این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
International Journal of Radiation Research، جلد ۶، شماره ۳، صفحات ۱۲۹-۱۳۴

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Determining rectal dose through cervix cancer radiotherapy by 9 MV photon beam using TLD and XR type T GAFCHROMIC® Film
چکیده انگلیسی مقاله Background: The goals of the present research were to investigate the rectal dose during four chosen techniques of cervical cancer radiotherapy and to examine how accurately the treatment planning represents dose measurements, and it’s practicality for routine use as well as, to determine the homogeneity of dose in tumor volume. Materials and Methods: The study was carried out using a Nepton 10-PC unit and a Rando phantom. The equipments which were used for dose determination were a Radiochromic densitometer with GAFCHROMIC® film (XR type T), and a thermo-luminescent dosimeter (TLD) reader system with TLD chips for rectal and target volume dose determination. Several techniques of external beam radiation therapy such as two-field (AP-PA), three-field and four-field with equal tumor dose and with equal applied dose were planned. Results: The maximum dose received by rectum was caused by two-field technique. The results of two dosimetry types were compared with each other as well as with the treatment planning, however, no statistically significant difference was observed between them (p > 0.05). In three-field, four -field with equal tumor dose and four-field with equal applied dose, rectal dose was lower, respectively 26.17%, 33.75% and 16.47%, than tumor dose. Conclusion: This study showed that dosimetry using TLD and film during radiotherapy could have a useful role as a predictor of choosing appropriate technique for preventing future rectal complications. Dose limitation to the rectum could possibly be achieved by using three-field and four-field techniques with equal tumor dose while maintaining a high dose to the tumor. Iran. J. Radiat. Res., 2008 6 (3): 129-134
کلیدواژه‌های انگلیسی مقاله Rectal dose, TLD, XR type T film, cervix cancer.

نویسندگان مقاله f ابراهیمی tazehmahalleh | f ebrahimi tazehmahalleh
department of medical physics, mashhad university of medical sciences, mashhad, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (Mashhad university of medical sciences)

h غلامحسینیان | h. gholamhosseinian
radiotherapy center of emam reza hospital, mashhad, iran


m لایق | m. layegh
radiotherapy center, omid hospital, mashhad, iran


n ابراهیمی tazehmahalleh | n ebrahimi tazehmahalleh
motahari clinic, khoy, azarbaijan, iran


h اسماعیلی | h. esmaily
department of bio-statistics, mashhad university of medical sciences, mashhad, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (Mashhad university of medical sciences)


نشانی اینترنتی http://www.ijrr.com/browse.php?a_code=A-10-1-289&slc_lang=en&sid=en
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده Radiation Biology
نوع مقاله منتشر شده تحقیق بدیع
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات