این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 18 آذر 1404
International Journal of Radiation Research
، جلد ۴، شماره ۱، صفحات ۱-۶
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Measurement of the immobilisation efficacy of a head fixation system
چکیده انگلیسی مقاله
Background: In order to assign appropriate planning target volume (PTV) margins, each centre should measure the patient positioning deviations for their set-up techniques. At the Royal Marsden Hospital, UK, a conformal shell (cast) system is used when a stereotactic frame is not suitable. In this paper, we report on a series of measurements with the aim of obtaining the systematic and random components of positioning error when using the above-mentioned shell system. Materials and Methods: The verification protocol was based on orthogonal pairs of anterior-posterior and lateral electronic portal images (EPIs) used to check the isocentre position. The isocentre verification results of paediatric patients were analysed. A practical ‘off-line’ patient set-up correction strategy had been used with the aim of reducing systematic errors. The verification protocol involved EPI acquisition on the first three fractions and then on a weekly basis. Additional images were taken if an isocentre movement was applied based on a 3 mm tolerance for a consistent 1D discrepancy. Results: Four patients required isocentre corrections ranging between 2 mm and 4 mm. Following the off-line corrections, the residual systematic errors in each direction were within 0.5 mm while the 1D random variation was about 1.0 mm. Conclusions: The head fixation system in conjunction with the correction strategy successfully kept the random and systematic positioning errors within an acceptable level well within the 3 mm tolerance. The measured components of positioning error can be used to define appropriate PTV margins.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
محمدعلی مصلح شیرازی | m a mosleh shirazi
department of radiotherapy, namazi hospital, shiraz university of medical sciences, shiraz, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)
h تایلر | h. taylor
department of radiotherapy, royal marsden hospital, sutton, surrey, uk
علی پاشا warrington | a p warrington
joint department of physics, royal marsden hospital and institute of cancer research, sutton, surrey, uk
f h ساران | f h saran
department of radiotherapy, royal marsden hospital, sutton, surrey, uk
نشانی اینترنتی
http://www.ijrr.com/browse.php?a_code=A-10-1-182&slc_lang=en&sid=en
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiation Biology
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات