این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 18 آذر 1404
International Journal of Radiation Research
، جلد ۴، شماره ۱، صفحات ۷-۱۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Developement a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code
چکیده انگلیسی مقاله
Background: Monte Carlo (MC) modeling of a linear accelerator is a prerequisite for Monte Carlo dose calculations in external beam radiotherapy. In this study, a simple and efficient model was developed for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code Materials and methods: The head of Elekta SL-25 linac was simulated for 6 and 18 MV photon beams using MCNP4C MC code. Energy spectra and fluence distribution of photons crossing the phase space plane were calculated. A simple point source model was developed based on calculated photon spectra and spatial distribution. Using this model, percent depth doses (PDDs) and beam profiles were calculated for different field sizes. The results of MC calculations were compared with measurements. Results: There was a good agreement between MC calculations and measurement for descending part of PDD curves. But, comparing calculated PDDs with measurement showed up to 10% differences for build up region of PDD curves for both energies. For beam profiles, there was 2% difference in flat region and up to 15% difference was seen for out of field region. These results were acceptable according to recommended criteria. Although, using our model the run time was decreased 24 times in comparison to original full Monte Carlo method. Conclusion: Our study showed that our model is accurate and effective for MC calculations in radiotherapy treatment planning. Also, it substantially lowers MC runtime for radiotherapy purposes.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
a مصباحی | a. mesbahi
medical physics department, medical school, tabriz university of medical sciences- iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تبریز (Tabriz university of medical sciences)
نشانی اینترنتی
http://www.ijrr.com/browse.php?a_code=A-10-1-183&slc_lang=en&sid=en
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiation Biology
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات