این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۱۶، شماره ۶، صفحات ۴۰۵-۴۰۹

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Determination of the Energy Windows for the Triple Energy Window Scatter Correction Method in Gadolinium-159 Single Photon Emission Computed Tomography Using Monte Carlo Simulation
چکیده انگلیسی مقاله Introduction: In radionuclide imaging, object scatter is one of the major factors leading to image quality degradation. Therefore, the correction of scattered photons might have a great impact on improving the image quality. Regarding this, the present study aimed to determine the main and sub-energy windows for triple energy window (TEW) scatter correction method using the SIMIND Monte Carlo simulation code in Gadolinium-159 (Gd-159) imaging. Material and Methods: The energy window was set for various main energy window widths (i.e., 10%, 15%, and 20%) and sub-energy window widths (i.e., 3 and 6 keV).Siemens Medical System Symbia fitted with a high-energy collimator was used with Gd-159 point source positioned at seven locations inside the cylindrical water phantom. A comparison was made between the true primary to total ratio (calculated by SIMIND) and the primary to total ratio estimated using TEW method. Results: The findings of this study showed that 20% of the main energy windows with 3 and 6 keV sub-energy windows were optimal for the implementation of the TEW method in Gd-159. Conclusion: According to the results, the optimal energy windows for Gd-159 scintigraphy were the sub-energy windows of 3 and 6 keV. These findings could be helpful in the quantification of Gd-159 imaging.Purpose : In radio-nuclides imaging, object scatter is one of major factors which leads to degradation of image quality. Therefore, the correction of scattered photons has a great impact to improve the image quality. The aim of this work was to determine the main and sub-energy windows for the triple energy window (TEW) scatter correction method using Monte Carlo simulation SIMIND code for Gadolinium-159 (Gd-159) imaging. Methods : Energy window was set for various main energy window width (10,15 and 20%) and sub energy window width (3 and 6 keV). Siemens Medical System Symbia fitted with High Energy collimator (HE) was imaged with Gd-159 point source positioned at seven locations inside cylindrical water phantom. The true primary to total ratio (calculated by SIMIND) and the primary to total ratio estimated using TEW method were compared.Results : A 20% of main energy window with 3 and 6 keV sub-energy windows were found to be optimal for implementation of the TEW method in Gd-159. Conclusion: The obtained results provide the optimal energy window for Gd-159 scintigraphy data and will aid the quantification of Gd-159 imaging.
کلیدواژه‌های انگلیسی مقاله Gd-159, Monte Carlo Simulation, object scatter, SPECT

نویسندگان مقاله | Youssef Bouzekraoui
Physics,Faculty of sciences, University Mohammed V Rabat


| FARIDA BENTAYEB
Departement of Physics, Laboratory of High Energy Physics, Modelling and Simulation, Faculty of Science, Mohammed V Agdal University, Rabat, Kingdom of Morocco


| Hicham Asmi
Physics, faculty of sciences, University Mohammed V Rabt


| Faustino Bonutti
Academic hospital of Udine



نشانی اینترنتی http://ijmp.mums.ac.ir/article_12370.html
فایل مقاله اشکال در دسترسی به فایل - ./files/site1/rds_journals/145/article-145-2060639.pdf
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات