این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
International Journal of Engineering، جلد ۲۷، شماره ۱۰، صفحات ۱۵۲۷-۱۵۳۶

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Employing Internal Flexible Wall as Mass Absorber in Tanks Subjected to Harmonic Excitations
چکیده انگلیسی مقاله The possibility of employing internal wall as mass absorber in rectangular water storage tanks subjected to harmonic ground motion excitation is investigated in this paper. Internal walls are used in these tanks usually for service performance purposes, which could be used as mass absorber to control seismic demand on tank's exterior walls. Derivation of the response of the coupled system including rigid external walls, flexible internal wall and fluid field is in frequency domain. The responses of the tank are evaluated subjected to harmonic excitations. By tuning the dynamic behavior of the tank and the sloshing liquid by changing the mass and stiffness of internal flexible wall, it is shown that wave elevation and water pressure on external rigid walls can be significantly reduced.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله marziye mousavi |
Civil Engieering, Islamic Azad University of Tabriz

saeed tariverdilo |
Civil Eng., Urmia Univ.

jahan mousavi |
Civil Engieering, Urmia University


نشانی اینترنتی http://www.ije.ir/article_72392_9f89dce09e3bae7634a58a214c5fa2c4.pdf
فایل مقاله اشکال در دسترسی به فایل - ./files/site1/rds_journals/409/article-409-2062635.pdf
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات