این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Dental Research Journal
، جلد ۱۷، شماره ۱، صفحات ۰-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Influence of calcium hydroxide residues after using different irrigants on the accuracy of two electronic apex locators: An in vitro study
چکیده انگلیسی مقاله
Background: The purpose of this study was to evaluate the effect of calcium hydroxide (Ca[OH] 2) residues on the accuracy of two electronic apex locators (EALs) (Root ZX and Raypex 6) in the presence of different irrigants. Materials and Methods: In this an in vitro study Eighty single‑rooted human mandibular premolars were selected. The crowns of the teeth were removed to standardize the working lengths (WLs). Actual WLs (AWLs) were recorded, and the root canals were shaped using protaper rotary instruments up to size F3. Then, the root canals were dried and filled with injectable Ca (OH) 2 paste and the access cavities were temporarily sealed. Teeth were put into four alginate boxes, including two experimental groups (n = 30) and two control groups (n = 10). The pools of alginate were wrapped in wet gazes and stored at 37°C and 100% humidity for 7 days. Then, the root canals were exposed and Ca (OH) 2 paste was removed by normal saline or 5.25% sodium hypochlorite irrigation followed by 17% ethylenediaminetetraacetic acid (EDTA), and the electronic WL (EWL) was measured by Root ZX and Raypex 6. Differences of EWL from AWL were calculated. Furthermore, the percentage of acceptable measurements (tolerance limit of ± 0.5 and ± 1 mm) was calculated for each apex locator. One‑way ANOVA test with post hoc paired t‑test and Chi‑square test was used to analyze the data (P < 0.05). Results: The results showed that there was no significant difference between the accuracy of two EALs and irrigants (P > 0.05). Conclusion: The present study revealed that no statistically significant differences were observed between the two apex locators after Ca(OH)2 paste removal with different irrigants.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Nooshin Sadat Shojaee
| Zahra Zaeri
| Mohammad Mehdi Shokouhi
| Fereshteh Sobhnamayan
| Alireza Adl
نشانی اینترنتی
http://drj.mui.ac.ir/index.php/drj/article/view/2075
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article(s)
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات