این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Journal of Dental Materials and Techniques، جلد ۹، شماره ۱، صفحات ۳۶-۴۲

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Dimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study
چکیده انگلیسی مقاله Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and additional silicone (Panasil) impression materials by the one-step and two-step impression techniques using perforated metal trays. The one-step impression technique was simultaneously performed with heavy body/light-body materials. In the two-step impression technique, acrylic copings with 2-mm thickness were placed on the abutments to obtain similar spacing for the light-body material. The dimensional accuracy of different impression materials and techniques were measured using distance differences of the stone dies from the master cast; subsequently, the results were compared with the reference model. Data were analyzed using a one-way analysis of variance and Dunnett’s tests (α=0.05). Results: All impression materials demonstrated an acceptable clinical accuracy. Identium (Vinyl siloxane ether) displayed the most accuracy in both the one-step and two-step impression techniques (P>0.05). The best accuracy for Panasil (additional silicone) was found to be the two-step impression technique (P>0.05), and the best accuracy for Speedex (condensation silicone) was reported as the one-step impression technique (P>0.05). Furthermore, the one-step impression technique was highly accurate in diameter dimension, as compared to the two-step impression technique. Conclusion: As evidenced by the results, the accuracy of impression is affected by the impression materials. Moreover, Identium (Vinyl siloxane ether) demonstrated the most accuracy in both one-step and two-step impression techniques.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله | Zahra Afshari
Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran


| Rahab Ghoveizi
Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran


| Layla Moein
Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran


| Mahdi Shamali
Department of Clinical Research, University of Southern Denmark, Odense, Denmark


| Sara Tavakolizadeh
Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran



نشانی اینترنتی http://jdmt.mums.ac.ir/article_14712.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Article
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات