این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
رایانش نرم و فناوری اطلاعات، جلد ۹، شماره ۱، صفحات ۳۶-۴۵

عنوان فارسی Estimation of Ear Parameters Applicable to Otoplasty Surgery
چکیده فارسی مقاله Analysis of facial color images is very important as a result of its numerous applications in facial surgeries. The development of different tools in the field of facial surgery analysis has helped surgeons before and after surgery. In this article, an Active Contour Model (ACM) based on Local Gaussian Distribution Fitting (LGDF) is introduced for the contour extraction of the ear area. The LGDF model is a region-based method in the Active Contour Model that unlike other models such as the Chan-Vese is not sensitive to intensity inhomogeneity of the image. After the contour extraction of the ear area, in the second step, with the four landmarks detection, ear parameters containing: length, width and external angle of ear were measured for analysis in the Otoplasty surgery. The proposed algorithm was evaluated on the AMI and Sahand University of Technology (SUT) databases. The proposed algorithm has an accuracy of %96.432, %97.423 and %85.546 in the AMI database and an accuracy of %98.381, %97.237 and %87.864 in the SUT database for the length, width and external angle of the ear parameters, respectively.
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Estimation of Ear Parameters Applicable to Otoplasty Surgery
چکیده انگلیسی مقاله Analysis of facial color images is very important as a result of its numerous applications in facial surgeries. The development of different tools in the field of facial surgery analysis has helped surgeons before and after surgery. In this article, an Active Contour Model (ACM) based on Local Gaussian Distribution Fitting (LGDF) is introduced for the contour extraction of the ear area. The LGDF model is a region-based method in the Active Contour Model that unlike other models such as the Chan-Vese is not sensitive to intensity inhomogeneity of the image. After the contour extraction of the ear area, in the second step, with the four landmarks detection, ear parameters containing: length, width and external angle of ear were measured for analysis in the Otoplasty surgery. The proposed algorithm was evaluated on the AMI and Sahand University of Technology (SUT) databases. The proposed algorithm has an accuracy of %96.432, %97.423 and %85.546 in the AMI database and an accuracy of %98.381, %97.237 and %87.864 in the SUT database for the length, width and external angle of the ear parameters, respectively.
کلیدواژه‌های انگلیسی مقاله Active Contour Model, Color Images Analysis, Analysis of Ear Anthropometry, Facial Surgery Analysis, Otoplasty Surgery

نویسندگان مقاله Ali Fahmi Jafargholkhanloo |
Faculty of Biomedical Engineering, Sahand University of Technology

Mousa Shamsi |
Faculty of Biomedical Engineering, Sahand University of Technology


نشانی اینترنتی http://jscit.nit.ac.ir/article_104387_b189e04d440ee6c282400104038dbc1d.pdf
فایل مقاله اشکال در دسترسی به فایل - ./files/site1/rds_journals/834/article-834-2465434.pdf
کد مقاله (doi)
زبان مقاله منتشر شده fa
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات