این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 18 آذر 1404
International Journal of Radiation Research
، جلد ۲۰، شماره ۱، صفحات ۱۴۵-۱۵۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Feasibility study of the best monitoring time-interval to track contrast agent bolus in dual-source coronary computed tomography angiography
چکیده انگلیسی مقاله
Background: To identify the best time-interval for dual-source coronary computed tomography angiography (CCTA) with bolus tracking automatic trigger technique. Materials and Methods: 120 patients were randomly divided into four groups (A, B, C and D), with 30 patients in each group. Monitoring was begun 10 seconds after injection, and the monitoring time-intervals for groups A, B, C and D were 1.14, 1.47, 2.00 and 3.00 seconds, respectively. CCTA acquisition was triggered as the monitored concentration in the region of interest (ROI) exceeded 100 HU. The monitoring times, CT and dose length product (DLP) values of the four groups were compared statistically. The quality of recorded CCTA images was evaluated objectively, and the image quality of blood vessel segments was accessed subjectively. Results: there were no statistically significant differences in objective evaluations between the four groups (P>0.05). Subjective evaluation results showed no statistically significant differences between groups A (1.879±0.042), B (1.876±0.043) and C (1.881±0.052). Group D showed the highest subjective score (2.923±0.069), which was significantly different from groups A, B, and C (P< 0.01). The monitoring times for groups A, B, C and D were 4.78±2.37, 3.76±1.39, 2.77±0.99 and 2.38±0.64, respectively; and the DLP values were 4.13±2.22, 2.18±0.80, 1.50±0.51 and 1.48±0.43 mGy·cm, respectively. DLP increases with increased monitoring times. Conclusion: When performing dual-source CCTA, a monitoring time-interval of 2 seconds with trigger scanning technique is the best choice, since it effectively reduces the radiation dose while providing satisfactory images.
کلیدواژههای انگلیسی مقاله
Dual source computed tomography, coronary computed tomography angiography, bolus tracking, radiation dose.
نویسندگان مقاله
| Y. Han
Department of Radiology, Third Central Hospital of Tianjin, Tianjin, 300170, China
| T. Wang
Department of Radiology, Third Central Hospital of Tianjin, Tianjin, 300170, China
| L. Lin
School of Medical Imaging, Tianjin Medical University, Tianjin, 300110, China
| Z. Liu
School of Medical Imaging, Tianjin Medical University, Tianjin, 300110, China
| Z. Liu
School of Medical Imaging, Tianjin Medical University, Tianjin, 300110, China
| Z. Liu
School of Medical Imaging, Tianjin Medical University, Tianjin, 300110, China
| T. Zhang
School of Medical Imaging, Tianjin Medical University, Tianjin, 300110, China
| L. Han
School of Medical Imaging, Tianjin Medical University, Tianjin, 300110, China
نشانی اینترنتی
http://ijrr.com/browse.php?a_code=A-10-2188-74&slc_lang=en&sid=1
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiobiology
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات