این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 17 آذر 1404
International Journal of Radiation Research
، جلد ۱۹، شماره ۳، صفحات ۶۸۵-۶۹۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Readout temperature effect on the response of the genipin gel dosimeter
چکیده انگلیسی مقاله
Background: The present study aimed to investigate the dependence of the response of the genipin gel dosimeter on readout temperatures. Materials and Methods: To this aim, after the gel preparation, they were exposed by a Varian Medical Linac accelerator with a dose range of 0-10 Gy. Then the irradiated samples were readout by a spectrophotometer device at 5°C, 10°C, 15°C and 20 °C temperatures. Results: Results revealed that the response of the genipin gel dosimeter is extremely temperature-dependent. For the mentioned readout temperatures, the maximum dose sensitivity was related to 10°C and its value was 35×10-3cm-1Gy-1. Investigation of the AUS (area under spectra) depicted that the maximum dose sensitivity was also related to 10°C. Furthermore, investigation of the dose resolution of this gel dosimeter showed that the minimum detectable dose was related to 10°C, and its amount was 0.24 Gy. Conclusion: The results confirmed a noticeable change in the response of the genipin gel dosimeter due to variations of the readout temperature. It can be concluded that the response sensitivity of this radiochromic gel dosimeter increased by readout temperature decreasing.
کلیدواژههای انگلیسی مقاله
Genipin gel dosimeter, dose sensitivity, readout temperature, dose resolution.
نویسندگان مقاله
| F. Bahrami
Department of Medical Radiation Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
| S.M.M. Abtahi
Physics Department, Imam Khomeini International University, Qazvin, Iran
| D. Sardari
Department of Medical Radiation Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
| M. Bakhshandeh
Department of Radiology Technology, Allied Medical Faculty, Shahid Beheshti University of Medical Sciences, Tehran, Iran
نشانی اینترنتی
http://ijrr.com/browse.php?a_code=A-10-2188-43&slc_lang=en&sid=1
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiobiology
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات