این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 18 آذر 1404
International Journal of Radiation Research
، جلد ۱۹، شماره ۳، صفحات ۷۰۳-۷۱۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Dose verification and plan conformity with three different dosimeters for intensity-modulated radiation therapy plans
چکیده انگلیسی مقاله
Background: The intensity-modulated radiotherapy (IMRT) enables personalized treatment; the complexity of this technique increased the need for patient-specific quality assurance (QA). Objective: Comparing three dosimeters that common for patient-specific QA of IMRT. Material and Method: cases were planned at Eclipse treatment planning system (TPS) to receive radiotherapy at Unique VARIAN linear accelerator LINAC; Patient-specific QA was performed with three independent dosimeters: Gafchromic films EPT2, Electronic Portal Image Device (EPID), and PTW 2D array. The absolute dose was measured and analysis of 2D gamma index was performed, then compared with the plan calculated in TPS. Results: Analysis of absolute dose measured have highest difference from dose in Gafchromic film (89.1±4) % while EPID had a lower range (96.6 ± 1.2) and 2Darray showed an agreement up to (99±1.2) for patient specific QA both EBT2 and EPID enable to compare the measured map with TPS calculations, for plan conformity the gafchromic film enable measurement with lower accuracy even with localized brain tumor, the heterogeneity in lung case slightly affect the EPID measurement, this found also with irregular surface of head and neck and increased depth within pelvic case examine. Measurement with 2D array found to be the optimum dosimeter within different conditions. Conclusion: different parameters might affect the accuracy of gafchromic film including film scanning, storing, and calibration curve. EPID has an average deviation appears in beam fluence and 2D array as a 2D ion chamber found to have the most accurate dosimeter, but still time consuming when compared to EPID.
کلیدواژههای انگلیسی مقاله
IMRT, patient-specific QA, 2D array, EBT2 Gafchromic film and EPID.
نویسندگان مقاله
| A. Yassin
Medical Physicist, Radiation Oncology Department, Al-Azhar University Hospital, Cairo, Egypt
| K. M. Elshahat
Radiation Oncology department, Faculty of Medicine, Al-Azhar University, Caro, Egypt
| E. M. Attlah
National Cancer Institute. Caro, Egypt
| H. Khaled
Radiation Oncology department, Faculty of Medicine, Al-Azhar University, Caro, Egypt
| A. Kany
Radiation Physics, Faculty of Science, Al-Azhar University, Cairo, Egypt
نشانی اینترنتی
http://ijrr.com/browse.php?a_code=A-10-2188-45&slc_lang=en&sid=1
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiobiology
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات