این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
International Journal of Radiation Research، جلد ۱۹، شماره ۲، صفحات ۲۵۹-۲۶۷

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی A new algorithm for dose calculation in heterogeneous lung phantoms under condition of small field size
چکیده انگلیسی مقاله Background: Current dose algorithms, such as the collapsed cone convolution algorithm and anisotropic analytical algorithm, are widely used in commercial treatment planning systems. Nevertheless, it is difficult to calculate the dose distribution of heterogeneities for small fields by using these algorithms, because of the electronic disequilibrium. However, contemporary treatment uses small beamlets more and more frequently, such as stereotactic body radiation therapy and intensity-modulated radiation therapy. In this study, a new inhomogeneity method in lung medium for small fields was presented. Materials and Methods: Inhomogeneous lung phantoms for different small fields were established, and different locations and thicknesses of lung media in inhomogeneous phantoms were also considered. The Monte Carlo code EGSnrc was used to calculate the density factor and the percentage depth-dose (PDD) distribution of lung phantoms. The PDDs were also calculated with the new algorithm, and then differences in the PDDs were determined. Results: The comparison shows that there is a good agreement between the new algorithm and the Monte Carlo code in different energy. The discrepancies of the three field sizes were less than 3%. With an increase in field size, the discrepancies were less than 1%. Even with changes in the location and thickness of the lung media in inhomogeneous phantoms, the discrepancies were always less than 1%. Conclusion: The comparative results revealed the effectiveness of the new algorithm in calculating depth-dose distribution, under different conditions, and that it can meet the requirements for calculating percentage depth dose distribution.  
کلیدواژه‌های انگلیسی مقاله Dose algorithm, small fields, inhomogeneous lung phantom, Monte Carlo simulation, percentage dose depth distribution.

نویسندگان مقاله | P. Yang
Sichuan University, Chengdu, Sichuan, China


| Z. Chen
Sichuan University, Chengdu, Sichuan, China


| Q. Lei
Nuclear Power Institute of China, Chengdu, Sichuan, China


| C. Yin
Sichuan University, Chengdu, Sichuan, China


| S. Zhang
Sichuan University, Chengdu, Sichuan, China


| C. Gou
Sichuan University, Chengdu, Sichuan, China


| C. Gou
Sichuan University, Chengdu, Sichuan, China



نشانی اینترنتی http://ijrr.com/browse.php?a_code=A-10-2055-110&slc_lang=other&sid=1
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده other
موضوعات مقاله منتشر شده Medical Physics
نوع مقاله منتشر شده تحقیق بدیع
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات