این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 17 آذر 1404
International Journal of Radiation Research
، جلد ۱۹، شماره ۲، صفحات ۳۹۱-۳۹۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Evaluation of full scatter convolution algorithm performance in the presence of inhomogeneities using a novel method of three-dimensional film dosimetry
چکیده انگلیسی مقاله
Background: Inclusion of air-filled cavities in the head and neck treatment fields due to electronic disequilibrium may lead to uncertainties in predicting dose distribution by treatment planning systems (TPS). In this study the Full Scatter Convolution Algorithm (FSC) used in TiGRT treatment planning systems was evaluated using a novel 3D film dosimetry method. Materials and Methods: 9 pieces of EBT2 films were embedded in a rectangular inhomogeneous head and neck phantom. Three approximately small field sizes including sandwiched EBT films which embedded between phantom slabs were exposed with 6 MV X-ray photons. A homemade computer code was developed in MATLAB for the creation of a 3D dose map of irradiated films and calculation of enclosed volumes which were surrounded by isodose lines in films. Then the calculated dose volumes were compared with the same quantities derived from Dose Volume Histogram (DVH) which is available in TPS outputs. Results: Our results showed significant differences between the results of the film dosimetry and DVH values. The maximum difference of calculated and measured values was observed in volumes surrounded by 95% isodose curves and 3x3cm2 field size (P=0.035) and the minimum difference was observed in volumes surrounded by 95% isodose curves and 5x5cm2 field size (P=0.047). Conclusions: The results of this study demonstrated overestimated results in volumetric dose calculation of the FSC dose calculation algorithm in the presence of inhomogeneities and the 3x3cm2 field size. Also, these results confirmed that the utilization of an accurate and comprehensive method such as 3D film dosimetry can be useful for TPS verification.
کلیدواژههای انگلیسی مقاله
3D film dosimetry, DVH, TPS, inhomogeneities.
نویسندگان مقاله
| A. Zeinali
Department of Medical Physics, Faculty of Medicine, Urmia University of Medical Sciences, Urmia, Iran
| L. Mahani
Department of Medical Physics, Faculty of Medicine, Urmia University of Medical Sciences, Urmia, Iran
| N. Kargar
Department of Medical Physics, Faculty of Medicine, Urmia University of Medical Sciences, Urmia, Iran
نشانی اینترنتی
http://ijrr.com/browse.php?a_code=A-10-2188-9&slc_lang=en&sid=1
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Medical Physics
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات