این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
International Journal of Radiation Research، جلد ۱۸، شماره ۴، صفحات ۶۴۷-۶۵۶

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Grading evaluation study of atlas based auto-segmentation of organs at risk in thorax
چکیده انگلیسی مقاله Background: The grading evaluation of atlas based auto-segmentation (ABAS) of organs at risk (OARs) in thorax was studied. Materials and Methods: Forty patients with thoracic cancer were included in this study, and for each thirteen thoracic OARs were delineated by an experienced radiation oncologist. The patients were randomly grouped into the training and the test dataset (20 each). The investigated ABAS strategies included single-atlas (Single), majority voting with 5 atlas matches (MV5) and simultaneous truth and performance level estimation (STAPLE) with 5 atlas matches (ST5). The Dice similarity coefficient (DSC), the difference of the Euclidean distance between centers of mass (ΔCMD), the difference of volume (ΔV), maximum Hausdorff distance (MHD) and average Hausdorff distance (AHD) between auto-segmented and manual contours were calculated. Results: Most of the index values (33/65) of ST5 were optimal. There were differences in the grading results for the five indexes. With DSC, five, four and four OARs were graded into Level 3, Level 2 and Level 1, respectively. The mean DSC values ranged from 0.88 to 0.96, from 0.73 to 0.79, and from 0.53 to 0.62 for the Level 3, Level 2 and Level 1, respectively. Conclusion: Grading evaluation of ABAS of thoracic OARs based on the DSC proved to be feasible and relatively more reliable. The thoracic OARs auto-segmentation was divided into three levels based on the DSC. Level 3 OARs can be auto-segmented, Level 2 OARs delineations need to be manually modified after the auto-segmentation, and Level 1 OARs are not recommended for the auto-segmentation.
کلیدواژه‌های انگلیسی مقاله Atlas based auto-segmentation, grading evaluation, thorax, organs at risk.

نویسندگان مقاله | Y.C. Ying
Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education and Center for Electronic Microscopy and Department of Physics, Wuhan University, Wuhan, China


| J.F. Cheng
Department of Radiation Oncology, Shanghai Chest Hospital Shanghai Jiao Tong University, Shanghai, China


| H. Wang
Department of Radiation Oncology, Shanghai Chest Hospital Shanghai Jiao Tong University, Shanghai, China


| H.L. Gu
Department of Radiation Oncology, Shanghai Chest Hospital Shanghai Jiao Tong University, Shanghai, China


| H. Chen
Department of Radiation Oncology, Shanghai Chest Hospital Shanghai Jiao Tong University, Shanghai, China


| Y. Shao
Department of Radiation Oncology, Shanghai Chest Hospital Shanghai Jiao Tong University, Shanghai, China


| Y.H. Duan
Department of Radiation Oncology, Shanghai Chest Hospital Shanghai Jiao Tong University, Shanghai, China


| A.H. Feng
Department of Radiation Oncology, Shanghai Chest Hospital Shanghai Jiao Tong University, Shanghai, China


| X.L. Fu
Department of Radiation Oncology, Shanghai Chest Hospital Shanghai Jiao Tong University, Shanghai, China


| H. Quan
Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education and Center for Electronic Microscopy and Department of Physics, Wuhan University, Wuhan, China


| Z.Y. Xu
Department of Radiation Oncology, Shanghai Chest Hospital Shanghai Jiao Tong University, Shanghai, China



نشانی اینترنتی http://ijrr.com/browse.php?a_code=A-10-2055-49&slc_lang=en&sid=1
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده Medical Physics
نوع مقاله منتشر شده تحقیق بدیع
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات