این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 1 دی 1404
Iranian Journal of Medical Physics
، جلد ۱۸، شماره ۶، صفحات ۴۰۳-۴۰۸
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Evaluation of Radiation Treatment Planning By Computed Tomography Metal Artifact Reduction Algorithm
چکیده انگلیسی مقاله
Introduction: The objective of this study was to evaluate the usefulness of Computed Tomography (CT) images acquired through repeated subtraction reconstruction algorithms to reduce metal artifacts in CT Treatment Planning System (TPS). Material and Methods: Origin images of Gammex phantom and Rando phantom and non-orthopedic metal artifact reduction (O-MAR) images were obtained after high density implantation. O-MAR applied images were also obtained. For evaluation of images, regions of interest (ROI) were set at five tissue rods and three points directly affected by artifacts in Gammex phantom. CT number and noise were compared and analyzed. Based on the investigated results using the Gammex phantom, three virtual cylinder target volumes were set on the Rando phantom to dose change of the radiation treatment planning according to the O-MAR. The average dose was then compared and analyzed. Results: CT number difference according to the application of O-MAR showed significant difference among lung and bone rod and 3 ROI directly affected. Noise difference according to O-MAR application was significantly different in rod except for bone rod. In the treatment plan using Rando phantom, non-O-MAR and O-MAR images showed -4.3 ~ 1.9% and -0.4 ~ 2.3% dose differences, respectively. Conclusion: Applying an O-MAR can reduce image distortion due to high-density implantation, improve image quality, and correct CT numbers.
کلیدواژههای انگلیسی مقاله
Metal, Artifact, Implants, CT Scan, Hounsfield units
نویسندگان مقاله
| Joowan Hong
Department of Radiological sciences, College of Health Sciences, Eulji University, Seongnam-si, Gyeonggi-Do, 13135, Republic of Korea
| Jihun Choi
Department of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-Do, 13620, Republic of Korea
| Jaeouk Ahn
Department of Medical IT Engineering, College of Medical Science, Soonchunhyang University, Asan, Chungnam, 31538, Republic of Korea
| Kyungjin Kim
Department of Medical IT Engineering, College of Medical Science, Soonchunhyang University, Asan, Chungnam, 31538, Republic of Korea
نشانی اینترنتی
https://ijmp.mums.ac.ir/article_17136.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات