عنوان انگلیسی Investigation of Noise Level and Spatial Resolution of CT Images Filtered with a Selective Mean Filter and Its Comparison to an Adaptive Statistical Iterative Reconstruction
چکیده انگلیسی مقاله Introduction: A simple noise reduction algorithm, i.e. a selective mean filter (SMF), had been previously introduced. The aim of this study is to investigate the image qualities filtered by a SMF and its comparison to an adaptive statistical iterative reconstruction (ASIR). Material and Methods: To assess the basic image quality, an American Association of Physicists in Medicine Computed Tomography (AAPM CT) performance phantom was used. The phantom was scanned by 128 Multiple Slices Computed Tomography. The tube current varied from 50 mA to 100, 150, and 200 mA. The images of a phantom were reconstructed by filtered back projection (FBP) followed by SMF and ASIR (20, 40, 60, 80, and 100%). The image quality assessment was in terms of noise level, noise power spectrum (NPS), and modulation transfer function (MTF). Results: The noise level and NPS of SMF was similar with ASIR 100%. The values of the MTF10 of the ASIR filter at any level and SMF were comparable. The MTF10 values of ASIR 60%, and SMF with 50 mA (low) were 0.76 ± 0.02 and 0.75 ± 0.02 cycle/mm, respectively. Meanwhile, the MTF10 of ASIR 60% and SMF with 200 mA (high) were 0.74 ± 0.00 and 0.73 ± 0.00 cycles/mm, respectively. Conclusion: Our results indicated that the performance of the SMF in reducing noise is equivalent to the maximum level of ASIR strength, i.e., ASIR 100%.
کلیدواژه‌های انگلیسی مقاله Computed Tomography, Image Quality, Algorithms, Image Processing, selective mean filter, adaptive statistical iterative reconstruction

نویسندگان مقاله | Ummu Zahro
Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia


| Choirul Anam
Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia


| Wahyu Budi
Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia


| Pandji Triadyaksa
Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia


| Jhon Saragih
Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia


| Dito Rukmana
Department of Radiology, Indriati Hospital Solo Baru, Jl. Palem Raya, Dusun III, Sukoharjo 57552, Central Java, Indonesia



نشانی اینترنتی https://ijmp.mums.ac.ir/article_16265.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات