این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۱۸، شماره ۴، صفحات ۲۶۳-۲۶۹

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Optimization of Energy Window and Collimator for Y-90 Bremsstrahlung SPECT imaging: A Monte Carlo Simulation Study
چکیده انگلیسی مقاله Introduction: In yttrium-90 imaging, image quality is highly dependent on the selection of energy window and collimator design becausetheY-90 bremsstrahlung photons have a continuous and broad energy distribution. The current study aimed to optimize the bremsstrahlung energy window setting and collimator for the improvement of both resolution and sensitivity. Material and Methods: In the present study, simulation of medical imaging nuclear detectors (SIMIND) Monte Carlo program was used to simulate Siemens Medical System Symbia. The SIMIND was utilized to generate the Y-90 bremsstrahlung single-photon emission computed tomography (SPECT) projection of the point source. Six energy windows settings and two collimators denoting medium energy and high energy were used in order to assess the effect of the energy window on the resolution. Results: The experimental measurements and simulation results showed a similar pattern in the point spread functions with the energy window. The simulation data indicated that the geometric component reached 73%for the energy window within the range of51-120keVusingthe high-energy (HE) collimator. In addition, the obtained results showed that the full width at half maximum (FWHM) and full width at tenth maximum (FWTM)(FWHM=7mm and FWTM=35mm)were higher in this window in comparison to those reported for other windows. Conclusion: According to the obtained results of the present study, the optimal energy window for Y-90 bremsstrahlung SPECT imaging was within the range of 51-120 keV. The obtained optimal energy window and optimal HE collimator had the potential to improve the image resolution and sensitivity of Y-90 SPECT images
کلیدواژه‌های انگلیسی مقاله Y, 90 SPECT imaging Monte Carlo

نویسندگان مقاله | Hicham Asmi
Department of Physics, LPHE, Modeling and Simulations, Faculty of Science, Mohammed V University, Rabat, Morocco


| Farida Bentayeb
Department of Physics,LPHE, Modeling and Simulations, Faculty of Science, Mohammed V University, Rabat, Morocco


| Youssef Bouzekraoui
Department of Physics,LPHE, Modeling and Simulations, Faculty of Science, Mohammed V University, Rabat, Morocco


| Faustino Bonutti
Academic Hospital of Udine, Department of Medical Physics, Udine, Italy


| sanae douama
Department of Physics,LPHE, Modeling and Simulations, Faculty of Science,Mohammed V University, Rabat, Morocco



نشانی اینترنتی https://ijmp.mums.ac.ir/article_15338.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات