این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۱۸، شماره ۳، صفحات ۱۵۴-۱۶۳

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Dosimetric Comparison of IMRT with 3D-CRT Regarding Their Contribution to the Treatment Plan Optimization Using Rando Phantom with a Realistic Lung Cancer Radiotherapy Treatment Planning
چکیده انگلیسی مقاله Introduction: This study compared a three-dimensional conformal radiation therapy (3D-CRT) with a recently implemented intensity modulation radiation therapy (IMRT) technique performed in the irradiation of lung cancer. The objective of this study is to demonstrate the dosimetric advantages of IMRT in target coverage, dose homogeneity, and reducing toxicity. Material and Methods: Depth point doses were compared as calculated by the Varian Eclipse treatment planning system (TPS) on virtual created patient and experimentally measured by thermoluminescence (TL) dosimetry. For treatment planning the same lesion of the real case with different volumes and structures contouring details were created on Rando anthropomorphic phantom computed tomography (CT) data. Dose measurement was performed by calibrated thermoluminescent detectors. Results: The difference between experimental TL measured doses and calculated doses in both techniques show mean values of ~3% (IMRT) and ~1% (3D-CRT) for high dose (>0.55Gy) and ~7% IMRT and 6.5% (3D-CRT) for low dose (< 0.55Gy). All IMRT optimized plans improved the heart (-28.3%), the spinal cord (-25.3%), and the left lung (-41.55%) sparing significantly, compared to the 3D-CRT plans. The optimized dose-volume histograms, the dose covering indices, and the dose profile across heterogeneity interfaces showed a significant improvement in dose conformity by IMRT. Conclusion: These findings demonstrate well that TL dosimetry when combined with suitable point dose measurement procedures can efficiently be used as an external and independent dose audit for the comparison between 3D-CRT and IMRT. IMRT with its dose-volume optimization algorithm can achieve a treatment plan quality in lung cancer radiotherapy unachievable by 3D-CRT.
کلیدواژه‌های انگلیسی مقاله Radiotherapy Planning Intensity, Modulated Radiotherapy Rando Anthropomorphic Phantom Thermoluminescence Dosimetry Radiotherapy Dosage 3D Conformal Radiotherapy

نویسندگان مقاله | Karim Benkahila
1. Department of Physics, Ferhat Abbas-Setif1University, Campus El-Bèz, Setif, Algeria 2. Laboratory of Dosing, Analysis and Characterization in high resolution, Campus El-Bèz, Setif, Algeria 3. Department of Radiotherapy, Fighting against Cancer Medical Centre, Sétif, Algeria


| Faycal Kharfi
1. Department of Physics, Ferhat Abbas-Setif1University, Campus El-Bèz, Setif, Algeria 2. Laboratory of Dosing, Analysis and Characterization in high resolution, Campus El-Bèz, Setif, Algeria


| Fouad Boulakhssaim
Department of Radiotherapy, Fighting against Cancer Medical Centre, Sétif, Algeria


| Saad Khoudri
Department of Radiotherapy, Fighting against Cancer Medical Centre, Sétif, Algeria



نشانی اینترنتی https://ijmp.mums.ac.ir/article_15052.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات