این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۱۷، شماره ۶، صفحات ۳۸۰-۳۸۵

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Validation of Motorized Wedge Effective Isodose Angle with a 2D Array Detector
چکیده انگلیسی مقاله Introduction: Elekta Versa HD linear accelerator is equipped with a universal wedge filter which is a single large physical wedge driven by motors; in other words, motorized wedge. It provides a nominal wedge isodose angle of 60° for the field size of 30×40 sq. cm. Motorized wedge isodose distribution generated is a combination of open and wedged beam segments. With this background in mind, the present study aimed to validate the planned wedge effective isodose angle. Material and Methods: The current study validated the planned wedge effective isodose angle for 15°, 30°, 45°, and 60° with 6MV and 15MV for 10x10 sq. cm and 20x20 sq. cm field size. To this end, an analytical formula was applied against a 2D array detector using PTW MultiCheck software. Results: As illustrated by the obtained results, the calculated, measured, and planned wedge effective isodose angle in this work represented a maximum deviation from its pre-set angle (a nominal wedge angle) of 9° for a 6MV photon energy and 5° for 15MV for field sizes of 10×10 sq. cm and 20×20 sq. cm. Conclusion: In the present study, we validated the planned wedge effective isodose angle for field sizes of 10x10sq. cm and 20x20sq. cm for 6MV and 15MV photon energies using an analytical method and 2D array detector with a reasonable agreement.
کلیدواژه‌های انگلیسی مقاله X, rays Radiometry Particle Accelerators Quality Control Radiotherapy Planning Computer, Assisted

نویسندگان مقاله | Jaimin Samabhai Gamit
MSc. Student of Medical Radiation Physics, School of Allied Health Sciences, Manipal Academy of Higher Education, Manipal


| shreekripa Rao
MSc. in Medical Radiation Physics, School of Allied Health Sciences, Manipal Academy of Higher Education, Manipal


| Jyothi Nagesh
MSc. in Medical Radiation Physics, Kasturba Medical College, Manipal Academy of Higher Education, Manipal


| Sarath S.Nair
MSc. in Medical Radiation Physics, School of Allied Health Sciences, Manipal Academy of Higher Education, Manipal


| Shambhavi Charan
MSc. in Medical Radiation Physics, School of Allied Health Sciences, Manipal Academy of Higher Education, Manipal


| Rechal Nisha Dsouza
MSc. in Medical Radiation Physics, School of Allied Health Sciences, Manipal Academy of Higher Education, Manipal


| Krishan Sharan
MD Radiotherapy, Kasturba Medical College, Manipal Academy of Higher Education, Manipal


| Srinidhi Chandraguthi
M.Sc. in Physics and post M.Sc Diploma in Radiological Physics, Kasturba Medical College, Manipal Academy of Higher Education, Manipal



نشانی اینترنتی https://ijmp.mums.ac.ir/article_14115.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات