این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۱۷، شماره ۶، صفحات ۳۸۶-۳۹۳

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Impact of Multi-criteria Optimization on 6-MV Flattening Filter-Free Volumetric Modulated Arc Therapy for Craniospinal Irradiation
چکیده انگلیسی مقاله Introduction: Volumetric modulated arc therapy (VMAT) is an advanced technique used for radiotherapy treatment using different optimization modes. The present study aimed to evaluate Multi-criteria Optimization (MCO) influence on VMAT for Craniospinal Irradiation. Material and Methods: Fifteen CSI patients treated with 23.4 Gy/13 fractions followed by a boost dose of 6-MV flattening filter-free beams were chosen for this study. Conventional VMAT (c-VMAT) plans were generated for Elekta Versa HD™ linear accelerator. Keeping all other parameters constant, c-VMAT plans combined with MCO (MCO-VMAT) were created for comparison. We compared homogeneity index (HI), conformity index (CI), planning target volume (PTV) dose coverage (D98%), organ at risk (OAR) dose, normal tissue integral dose (NTID), volume receiving ≥ 5 Gy and ≥ 10 Gy by normal tissue, delivery time (DT), monitor units (MUs), and calculation time (CT). Results: Our findings demonstrated that HI and CI improved slightly in MCO-VMAT, in comparison with c-VMAT (P>0.05). No significant dose difference was observed in D98% for PTV and volume receiving the dose of ≥ 5 Gy, ≥ 10 Gy, and NTID (P>0.05). A slight increase was found in maximum dose to PTV in VMAT-MCO, compared to c-VMAT (P>0.05). The mean dose, max dose, and dose received by OAR were significantly lower in VMAT-MCO as compared to c-VMAT (p < 0.05). The MU, CT, and DT were noticed to be lower in c-VMAT than MCO-VMAT (P>0.05). Conclusion: The MCO-VMAT can be used for CSI, without compromising target coverage, reduced OAR dose by accepting a slight increase of MUs, delivery and calculation time as compare to c-VMAT.
کلیدواژه‌های انگلیسی مقاله Craniospinal Irradiation Monaco™ Multi, Criteria Optimization Volumetric Modulated Arc Therapy

نویسندگان مقاله | Mohandass P
Department of Physics, School of Sciences, Arts, Media, and Management, Karunya Institute of Technology and Sciences, Coimbatore, Tamilnadu, India


| KHANNA D
Department of Physics, School of Sciences, Arts, Media, and Management, Karunya Institute of Technology and Sciences, Coimbatore, Tamilnadu, India


| Selvaganapathi A
Department of Radiation Oncology, Fortis Cancer Institute, Fortis Hospital, Mohali, Punjab, India


| Nishaanth B
Department of Radiation Oncology, Fortis Cancer Institute, Fortis Hospital, Mohali, Punjab, India


| Saravanan C
Department of Radiation Oncology, Fortis Cancer Institute, Fortis Hospital, Mohali, Punjab, India


| Thiyagaraj T
Department of Radiation Oncology, Fortis Cancer Institute, Fortis Hospital, Mohali, Punjab, India


| Narendra Kumar Bhalla
Department of Radiation Oncology, Fortis Cancer Institute, Fortis Hospital, Mohali, Punjab, India


| a Puri
Department of Radiation Oncology, Fortis Cancer Institute, Fortis Hospital, Mohali, Punjab, India


| Blessy M
Chitkara School of Health Sciences, Chitkara University, Punjab, India



نشانی اینترنتی https://ijmp.mums.ac.ir/article_14353.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات