Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
چکیده انگلیسی مقاله
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(methyl methacrylate) phantom was used for quality control test on CT scanners. Data of 214 scan parameters, dose indicators; volume CT dose index (CTDIvol) and dose-length product (DLP) of patients who underwent cranial CT scans were collected. The data were grouped into three, with respect to the slice numbers of 24, 28, and 32. Tube voltage (kVp) and slice thickness were constant; (110 kVp and 4.8 mm, respectively), at variable tube currents (mAs). A one-sample t-test was used to compare the dose indicator values of the hospital protocol with a recommended protocol. Scan parameters were optimized for radiation dose against image quality. Results: Increased mAs resulted in increased CTDIvol and DLP at constant kVp and slice thickness. Moreover, dose indicators recorded the lowest and highest values at the slice numbers of 24 and 32, respectively. An increase in slice numbers affected dose indicators. Dose indicators recorded significant reduction (p < 0.001) in comparison to the recommended protocol. Conclusion: Optimization of CT protocol considers radiation dose and image quality. Radiologists adopted protocols acquired with lower scan parameters and dose indicators lower than the recommended achievable dose limit of 58 mGy.
کلیدواژههای انگلیسی مقاله
optimization, Image Quality, Radiation Dose, Computed Tomography
نویسندگان مقاله
| Nnamdi O.E. Okoro
Department of Radiology and Radiotherapy Technology, International Campus, Tehran University of Medical Sciences, Tehran, Iran.
| Vahid Changizi
Department of Radiology and Radiotherapy Technology, School of Allied Medical Sciences, Tehran University of Medical Sciences, Tehran, Iran.
| Elahe Jazayeri Ghareh Bagh
Department of Radiology and Radiotherapy Technology, School of Allied Medical Sciences, Tehran University of Medical Sciences, Tehran, Iran.
| Farideh Pak
Department of Radiology and Radiotherapy Technology, School of Allied Medical Sciences, Tehran University of Medical Sciences, Tehran, Iran.
نشانی اینترنتی
https://ijmp.mums.ac.ir/article_13459.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات