این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 23 آذر 1404
Dental Research Journal
، جلد ۱۷، شماره ۶، صفحات ۰-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Evaluation of reverse torque values and failure loads of three different abutment designs with internal connections
چکیده انگلیسی مقاله
Background: High percentage of biomechanical complications such as screw loosening in dental implants can be related to implant–abutment (I/A) connection properties which affect the behavior of implant assembly against functional loads in the oral cavity. The aims of the present study were to compare the reverse torque values (RTVs) and failure loads of three abutment types with internal Morse taper connection. Materials and Methods: In this experimental in vitro study, eighteen implants (4.5 mm × 10 mm bone level implants, Implantium, Dentium Co, Seoul, South Korea) were divided into three groups with different abutments: two‑piece (TP) abutment, one‑piece (OP) abutment, and screw abutment (SA), mounted in stainless‑steel blocks according to ISO 14801. After completion the torque/detorque protocol, a compressive load (1 mm/min) was applied at 30° off‑axis until failure. Mean reverse torque/tightening torque (RT/TT) values and failure loads were analyzed with one‑way ANOVA test and Tukey’s honest significant difference (α = 0.05). Failure modes were evaluated by radiography and stereomicroscopy. Results: RT/TT values in the TP group were lower than those in other groups (P < 0.001). Highest failure loads were observed in SA group (P = 0.002). In radiographic evaluation, all specimens showed deformation in I/A interface. Conclusion: I/A connections with larger surface areas may lead to higher RTVs (e.g., OP and SA groups). Use of an additional screw and indexed area in TP group did not reduce the bending resistance under static loading. Key Words: Compressive loading, dental implant–abutment interface, reverse torque
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Saied Nokar
| Habib Hajimiragha
| Leyla Sadighpour
| Azam Sadat Mostafavi
نشانی اینترنتی
http://drj.mui.ac.ir/index.php/drj/article/view/2156
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article(s)
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات