این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 21 آذر 1404
Dental Research Journal
، جلد ۱۷، شماره ۴، صفحات ۰-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Accuracy of digital image enhancement in detection of vertical and horizontal root fracture
چکیده انگلیسی مقاله
Background: Two‑dimensional intraoral radiography is the most common tool for recognizing root fractures. Improving the quality of images by means of enhancement tools can increase the recognition power of them. The aim of this study is to evaluate the effect of digital image enhancement on vertical and horizontal root fractures (HRFs) diagnostic accuracy. Materials and Methods: In this in vitro study, 100 human extracted teeth, involving 50 mandibular premolars and 50 maxillary incisors, were investigated. In total, 25 premolar teeth were vertically fractured and other 25 sound teeth served as testing group. According to the verified methods, 25 incisor teeth were fractured and other 25 teeth of this group served as testing ones. Following, by using the charge‑coupled device sensor, preapical digital images were recorded. The original images were altered using reverse‑contrast and colorization enhancement tools. Two different observers independently investigated all of the images. Receiver operating characteristic analysis was used to calculate the area under the curve (AUC) and sensitivity and specificity of all images. Data analyzde using receiver operating characteristic (ROC) analysis. Two‑ways variance analysis was used to assess differences in the values (P = 0.05 ). Results: AUC and sensitivity and specificity related to the original, reverse‑contrast, and colorized images were calculated (0.84, 0.64, 0.99), (0.84, 0.64, 0.96), and (0.82, 0.64, 0.92) respectively, for vertically root fractured images. AUC and sensitivity and specificity related to the original, reverse‑contrast, and colorized images were calculated (0.49, 0.44, 0.56), (0.50, 0.44, 0.60), and (0.48, 0.48, 0.48), respectively, for horizontally root‑fractured images. Conclusion: The results of the present study revealed that reverse‑contrast and colorized enhancement filters cannot be used as critical methods in detecting in vitro vertical and HRF.
کلیدواژههای انگلیسی مقاله
Digital radiography, endodontics, root fracture
نویسندگان مقاله
| Maryam Ghazizadeh
| Mahnaz Sheikhi
| Maedeh Aminian
| Mohammad Moein Ghazizadeh
نشانی اینترنتی
http://drj.mui.ac.ir/index.php/drj/article/view/2129
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article(s)
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات