این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Middle East Journal of Cancer، جلد ۱۲، شماره ۴، صفحات ۵۱۶-۵۲۶

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی The Effect of the Number of Fields on Radiotherapy Plans of Breast Cancer Patients in Three-Dimensionally Conformal Radiotherapy Plans: Dosimetric Studies
چکیده انگلیسی مقاله Background: The objective of this study was to compare the dosimetric outcome of plans with more fields to those with fewer ones for breast cancer patients. Method: 23 breast cancer patients were examined in this experimental study. Two groups of these patients were planned by treatment planning system. The number of beams was changed for each group, and the dosimetric parameters were calculated. The dose volume histogram (DVH) and the statistical analyses were performed for the two plans of all patients. Results: The DVH for the planning target volume (PTV) of the two techniques was estimated. Optimized plans were carried out to ensure that 95 % of the target volume takes 95 % of the dose. Based on the statistical analysis, the best coverage of dose had no relationship with the number of beams because the P-value of V105 %, V95%,V110%, Dmean, Dmax, conformity index, homogeneity index, and D5% were 0.9537, 0.9152, 0.3446, 0.8156, 0.9516, 0.7888, 0.2127, and 0.7282, respectively. The Mean ± standard error of mean for all PTV parameters was nearly the same. Also, the organ at risk had no significant difference after changing the number of beams, which means that the complication to normal tissue was nearly the same for both plans. Conclusion: The number of beams has no effect on PTV and normal tissue. Therefore, it is important for medical physicists to conduct the optimized plan without exceeding the number of beams to reduce the scattered radiation.
کلیدواژه‌های انگلیسی مقاله Breast neoplasms, 3D, Conformal, Radiotherapy, DVH

نویسندگان مقاله Zezy Mansour Bazeed |
Department of Clinical Oncology and Nuclear Medicine, Faculty of Medicine, Mansoura University, Mansoura, Egypt

Ehab Maarouf Attalla |
Department of Physics, Division of Medical Physics, National Cancer Institute, Cairo University, Egypt

Ibrahim Ali Mohamed Awad |
Department of Clinical Oncology and Nuclear Medicine, Faculty of Medicine, Mansoura University, Mansoura, Egypt

Maysa Ismail Abdel Hamid |
Polymer Research Group, Physics Department, Faculty of Science, Mansoura University, Mansoura, Egypt

Afaf Sarhan |
Polymer Research Group, Physics Department, Faculty of Science, Mansoura University, Mansoura, Egypt


نشانی اینترنتی https://mejc.sums.ac.ir/article_47503_9abcf001c776081b6f549b3516ae03ae.pdf
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات