این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Journal of Medical Bacteriology، جلد ۱۰، شماره ۳-۴، صفحات ۳۹-۵۰

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Microbial Contamination and Public Health Risk Associated with the Use of Biometric Fingerprinting Clocking Device in Ekiti State, Nigeria
چکیده انگلیسی مقاله Background:       The biometric fingerprinting clocking devices are now commonly being used in Nigeria to record human biodata. This system involves physical contact between the skin and surface of the device, which is likely to be contaminated by microorganisms of multiple users. This study aimed to investigate the role of biometric fingerprinting clocking devices as a potential source for microbial contaminants spreading. Methods:       This study was conducted from February to May 2018 and involved samples collected from the surfaces of the biometric fingerprinting device using sterile swabs. Samples were inoculated on MacConkey, Blood, Nutrient, and Sabouraud dextrose agar media and incubated aerobically at 37oC for 24 hours. Colonies from the agar media were characterized biochemically to identify microbial species and their antibiotic susceptibility test was determined by the Kirby Bauer disc diffusion method. Results:       Totally, 221 samples (92%) containing microbial organisms grew. Bacteria isolated included: Staphylococcus aureus (29.6%), Escherichia coli (19.4%), Bacillus species (17.43%), Klebsiella species (10.2%), Streptococcus species (8.55%), Pseudomonas spp (7.24%), Proteus spp (2%) and Enterococcus spp (0.66%). The majority of the bacteria were resistant to at least two antibiotics used. The fungi isolated were Trichophyton mentagrophytes (25%), Trichophyton rubrum (20%), Epidermophyton species (19%), Mucor species (17%), Aspergillus species (11%), and Microsporum species (5%) to decrease occurrence. Conclusion:       Hand disinfection with a proper cleaning regimen is recommended to reduce contamination on the biometric fingerprinting clocking devices.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله | Akinseye Janet Funmilayo
Department of Medical Laboratory Science, College of Medicine and Health Sciences, Afe Babalola University, Ado-Ekiti, Nigeria


| Ajayi Deborah Damilola
Department of Medical Laboratory Science, College of Medicine and Health Sciences, Afe Babalola University, Ado-Ekiti, Nigeria


| Oluboyo Bernard Oluwapelumi
Department of Medical Laboratory Science, College of Medicine and Health Sciences, Afe Babalola University, Ado-Ekiti, Nigeria


| Oluwapelumi Yomi
Department of Medical Laboratory Science, College of Medicine and Health Sciences, Afe Babalola University, Ado-Ekiti, Nigeria


| Ayuba Sunday Buru
Department of Medical Laboratory Science, College of Medicine and Health Sciences, Afe Babalola University, Ado-Ekiti, Nigeria



نشانی اینترنتی https://jmb.tums.ac.ir/index.php/jmb/article/view/468
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات