این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Journal of Health Sciences and Surveillance System، جلد ۱۰، شماره ۱، صفحات ۸۳-۸۷

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Midterm Follow-up and Outcome of Pacemakers in Children: A Single Center Experience
چکیده انگلیسی مقاله Background: Pacemaker implantation is an effective life-long treatment in patients with atrioventricular block to generate a reliable heartbeat. Choosing between epicardial and endocardial (trans-venous) techniques in children is based on the cardiac center experience and each technique has some benefits and risks. Methods: In this observational cross-sectional study, we reviewed file-records of 186 under 18- year-old patients who underwent cardiac pacemaker implantation due to atrioventricular block. All of endocardial implantations had been performed by experienced pediatric cardiologists and all epicardial pacemakers by experienced cardiac surgeon from 2006 to 2018 in Namazi and Faghihi hospitals in Shiraz, Iran. Results: One hundred and five patients had epicardial pacemaker and 81 patients had endocardial pacemaker. One hundred and seventy-eight patients had postoperative complete heart block after correction of congenital cardiac abnormality due to the destruction of conductive pathway. Eight patients were born with complete heart block. Four (2.15%) patients in the endocardial group developed pacemaker related infection. Two (1%) patients had sudden cardiac death after pacemaker insertion in the follow-up; Medtronic single chamber pacemaker was inserted for one patient who had complete heart block after surgical ventricular septal defect closure. However, a month later she expired due to sudden cardiac arrest during exercise and one patient after correction of complete atrio-ventricular septal defect had pacemaker insertion and sudden death, 3 months after pace insertion (1.12%); none of them had history of palpitation, syncope, arrhythmia in their post-operation electrocardiography, or tachycardia in their pacemaker analysis. Conclusion: In Conclusion, epicardial pacemaker has a noticeable battery longevity in comparison to endocardial pacemakers and fewer valvular complications and endocarditis cases. Also, it appears that increasing size and vessel stiffness followed by aging can prime better vascular access and less lead malfunction in older pediatrics in endocardial approach; however, the site of ventricular pacing is still a puzzle because of the effect of pacing site on left ventricle synchrony and ejection fraction.
کلیدواژه‌های انگلیسی مقاله Patient outcome assessments, Cardiac pacing, Artificial pacemaker

نویسندگان مقاله Hamid Amoozgar |
Neonatal Research Center, Shiraz University of Medical Sciences, Shiraz, Iran

Effat Majidi |
Department of Pediatric, Medical School, Shiraz University of Medical Sciences, Shiraz, Iran

Nima Mehdizadegan |
Department of Pediatric, Medical School, Shiraz University of Medical Sciences, Shiraz, Iran

Mohammad Reza Edraki |
Department of Pediatric, Medical School, Shiraz University of Medical Sciences, Shiraz, Iran

Amir Naghshzan |
Neonatal Research Center, Shiraz University of Medical Sciences, Shiraz, Iran

Hamid Mohammadi |
Neonatal Research Center, Shiraz University of Medical Sciences, Shiraz, Iran


نشانی اینترنتی https://jhsss.sums.ac.ir/article_48118_3664055d45477d74e315f219d6e9d927.pdf
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات