The Archives of Bone and Joint Surgery
، جلد ۹، شماره ۴، صفحات ۴۳۲-۴۳۸
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
The Accuracy of 3D Printed Carpal Bones Generated from Cadaveric Specimens
چکیده انگلیسی مقاله
Background: Computer assisted three-dimensional (3D) printing of anatomic models using advanced imaging haswide applications within orthopaedics. The purpose of this study is to evaluate the 3D printing accuracy of carpalbones.Methods: Seven cadaveric wrists underwent CT scanning, after which select carpal bones (scaphoid, capitate, lunate,and trapezium) were dissected in toto. Dimensions including length, circumference, and volume were measured directlyfrom the cadaver bones. The CT images were converted into 3D printable stereolithography (STL) files. The STL fileswere converted into solid prints using a commercially available 3D printer. The 3D printed models’ dimensions weremeasured and compared to those of the cadaver bones. A paired t-test was performed to determine if a statisticallysignificant difference existed between the mean measurements of the cadavers and 3D printed models. The intraclasscorrelation coefficients (ICC) between the two groups were calculated to measure the degree of agreement.Results: On average, the length and circumference of the 3D printed models were within 2.3 mm and 2.2 mm,respectively, of the cadaveric bones. There was a larger discrepancy in the volume measured, which on average waswithin 0.65 cc (15.9%) of the cadaveric bones. These differences were not statistically significant (P > 0.05). Therewas strong agreement between all measurements except the capitate’s length and lunate’s volume.Conclusion: 3D printing can add value to patient care and improve outcomes. This study demonstrates that 3D printingcan both accurately and reproducibly fabricate boney models that closely resemble the corresponding cadaveric anatomy.Level of evidence: V
کلیدواژههای انگلیسی مقاله
cadaver, Carpal bones, Computed Tomography (CT), Three-dimensional (3D)
نویسندگان مقاله
| Cory Lebowitz
Rowan University School of Osteopathic Medicine, Stratford, NJ, USA
| Joseph Massaglia
Rowan University School of Osteopathic Medicine, Stratford, NJ, USA
| Christopher Hoffman
Department of Hand & Upper Extremity Surgery, Thomas Jefferson University, Philadelphia, PA, USA
| Ludovico Lucenti
Department of Hand & Upper Extremity Surgery, Thomas Jefferson University, Philadelphia, PA, USA
| Sachin Dheer
Department of Radiology, Thomas Jefferson University Hospitals, Cherry Hill, NJ, USA
| Michael Rivlin
Department of Hand & Upper Extremity Surgery, Thomas Jefferson University, Philadelphia, PA, USA
| Pedro Beredjiklian
Department of Hand & Upper Extremity Surgery, Thomas Jefferson University, Philadelphia, PA, USA
نشانی اینترنتی
https://abjs.mums.ac.ir/article_17005.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
RESEARCH PAPER