این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 23 آذر 1404
The Archives of Bone and Joint Surgery
، جلد ۹، شماره ۱، صفحات ۱۰۲-۱۰۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Intra- and Inter-Session Reliability of Methods for Measuring Reaction Time in Participants with and without Patellofemoral Pain Syndrome
چکیده انگلیسی مقاله
Background: To evaluate the relative and absolute reliability of reaction time measuring methods during differentconditions in participants with and without patellofemoral pain syndrome (PFPS).Methods: 30 patients with PFPS and 30 healthy controls were recruited in the present study. The upper extremityreaction time, upper extremity error rate, involved and non-involved lower extremity braking reaction times, and involvedand non-involved knee extension reaction times were measured. Each condition was repeated three times, 2 sessionswith a 5-7 days interval. The intra-session reliability was evaluated in three-trial (A), second- and third-trial (B) modes.In addition, the inter-session reliability was evaluated in mode A, mode B, and best score (C) mode.Results: The result of inter-session reliability of mode A showed that all measurements except upper extremity reactiontime in PFPS group showed high to very high relative reliability (ICC: 0.74-0.94). In mode B, all measurements exceptnon-involved knee extension reaction time in PFPS group showed high to very high relative reliability (ICC: 0.71-0.93).In mode C, all measurements showed high to very high relative reliability (ICC: 0.70-0.94) except upper extremity errorrate and non-involved knee extension reaction time in PFPS group. The result of intra-session reliability showed thatall measurements had high to very high relative reliability (ICC: 0.78-0.94) in mode A. In mode B, all measurementsshowed high to very high relative reliability (0.78-0.94).Conclusion: The braking time seems more reliable than other reaction time tasks. In addition, the results showedthat mode A is more reliable than other modes. The newly designed package is a reliable tool to measure the kneeextension reaction time in patients with knee musculoskeletal disorders.Level of evidence: II
کلیدواژههای انگلیسی مقاله
knee, patellofemoral pain syndrome, Reaction time, Reliability
نویسندگان مقاله
| Afsaneh Zeinalzadeh
Department of Physiotherapy, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| Salman Nazary-Moghadam
Department of Physiotherapy, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| Sayyed Hadi Sayyed Hoseinian
Orthopedic Research Center, Shahid Kamyab Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
| Mohammad H. Ebrahimzadeh
Orthopedic Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| Esmaeel Imani
Department of Physiotherapy, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| Samira Karimpour
Department of Physiotherapy, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
نشانی اینترنتی
https://abjs.mums.ac.ir/article_16545.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
RESEARCH PAPER
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات