این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 5 دی 1404
دانشور پزشکی
، جلد ۱۶، شماره ۳، صفحات ۴۵-۵۲
عنوان فارسی
بررسی اصلاح قوز قرنیه با استفاده از قطعات حلقوی داخل قرنیهای فرارا
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
شاخص توده بدنی، چاقی، بارداری،
عنوان انگلیسی
Evaluation of Keratoconus Correction by Ferrara Intracorneal Ring Segments
چکیده انگلیسی مقاله
Background and Objective: Evaluation of the results, safety, and stability of ferrara intracorneal ring segment (FICRS) implantation for Keratoconus correction (age range was 24.39±8.32 years). Materials and Methods: In this clinical trial study, 64 eyes of 57 patients with keratoconus and clear cornea that had FICRS implantation were studied. Uncorrected visual acuity (UCVA), best-spectacle corrected visual acuity (BSCVA), refractive errors, and corneal data from Orb scan II, and complications were analyzed. Results: The follow-up was 18 months ± 6.45 (SD), the UCVA improved from 1.14 logarithm of the minimum angle of resolution (Log MAR) ± 0.53 (SD) to 0.48 og MAR ± 0.44 (SD) (P≤ 0.001) and the BSCVA improved from 0.44 Log MAR ± 0.40 (SD) to 0.23 Log MAR ± 0.19 (SD) (P≤ 0.001). Improvement of main outcome measures were as follows: 4.90 diopter (D) ± 3.33 (SD) for Spherical equivalent (P≤ 0.001), 4.16 D ±3.24 (SD) for Spherical refractive error (P≤ 0.001), 1.49±2.31 (SD) for cylindrical refractive error (P≤ 0.001). Corneal topography showed more improvement of corneal uniformity and irregular astigmatism. Minimum and maximum central corneal powers decreased 1.75 D±5.94 (SD) (P≤ 0.03) and 4.75 D±3.33 (SD) (P≤ 0.001), respectively. Significant decrease in anterior corneal curvature and posterior best-fit sphere curvature were observed. Segment extrusion one eye (16%), superficial position 1 eye (1.6%), and infectin in 5 eyes (7.8%) had occurred. Conclusion: During 18 months, FICRS implantation improved both UCVA and BSCVA, however, it reduced corneal steepening and astigmatism. Whereas, increased topographic regularity. FICRS implantation was a safe procedure that had led to stable results. This procedure prevented or delayed corneal graft in many cases.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
دکتر حسن قاسمی |
دکتر حسن رزمجو |
دکتر سیامک بلالی |
دکتر یوسف واهب |
نشانی اینترنتی
http://daneshvarmed.shahed.ac.ir/article_1336_4a86ef5de00ddd067ce6c9b369443da3.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
fa
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات