این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 24 آذر 1404
The Archives of Bone and Joint Surgery
، جلد ۱۰، شماره ۱۲، صفحات ۱۰۲۶-۱۰۲۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Reliability of Routine Radiographs for Conservatively Treated Metacarpal Shaft and Neck Fractures
چکیده انگلیسی مقاله
Background: To investigate the reliability of orthopedic hand surgeons to evaluate radiographic healing in initial andfollow-up radiographs of the conservatively treated metacarpal shaft and neck fractures. The rationale for this studywas to reduce the rate of unnecessary, routine radiographs when treating metacarpal fractures.Methods: Forty sets of digital x-rays, twenty at the initial visit and twenty at the 4-week follow-up, were randomlyselected and reviewed. Three hand surgeons evaluated the x-rays for (1) fracture location, (2) radiograph timing,(3) healing status, (4) percentage healed, (5) angulation, and (6) confidence in healing status. Observers reviewedstudies in random order and evaluated the same set of radiographs one month after the initial review. Intra- andinterobserver agreements were analyzed using Fleiss’ kappa (κ) for all parameters and all possible observerpairings.Results: Interobserver and intraobserver reliability was highest when evaluating fracture location and lowest whenassessing the percentage healed. The interobserver reliability was fair for radiograph timing and healing status andfair-to-moderate for angulation. The intraobserver reliability was moderate for radiograph timing and healing status andmoderate-to-substantial for angulation. Observers correctly differentiated initial vs. follow-up images 62% of the timeand reported to feel somewhat certain in their evaluation of healing status.Conclusion: When evaluating initial and 4-week follow-up radiographs, hand surgeons were somewhat confidentin their assessment of healing but had less than substantial intra- and interobserver reliability following radiographicevaluation. Due to their poor reproducibility, routine radiographs may be unnecessary when evaluating conservativelytreated metacarpal fractures. Further studies and guidelines that identify clear indications for the use of routine imagingin metacarpal fracture care are warranted.Level of evidence: II
کلیدواژههای انگلیسی مقاله
Fracture, metacarpal, radiographs, Reliability, X-Ray
نویسندگان مقاله
| Terence Thomas
Thomas Jefferson University, Philadelphia, PA, USA
| Tyler Henry
Thomas Jefferson University, Philadelphia, PA, USA
| Justin Kistler
Thomas Jefferson University, Philadelphia, PA, USA
| Daniel Seigerman
Thomas Jefferson University, Philadelphia, PA, USA
| Jacob Tulipan
Thomas Jefferson University, Philadelphia, PA, USA
| Pedro Beredjiklian
Thomas Jefferson University, Philadelphia, PA, USA
نشانی اینترنتی
https://abjs.mums.ac.ir/article_21388.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
RESEARCH PAPER
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات