این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
The Archives of Bone and Joint Surgery، جلد ۱۰، شماره ۱۱، صفحات ۹۱۶-۹۳۶

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Revision in Ceramic-on-Ceramic and Ceramic-on- Polyethylene Bearing in Primary Total Hip Arthroplasty with Press-fit Cups: A Systematic Review and Metaanalysis of Different Methodological Study Designs
چکیده انگلیسی مقاله Background: The influence of bearing on revision, especially in press-fit modular cup total hip arthroplasty (THA),remains underexposed.Methods: A systematic literature review was conducted in PubMed, Embase, Cochrane Library, and ClinicalTrials.gov in line with the PRISMA guidelines. The primary outcome was an overall revision between ceramic-on-ceramic(CoC) and all sorts of ceramic-on-polyethylene (CoPE) bearings. As secondary outcomes complications and reasons forrevision were compared between bearings. Outcomes were presented in subgroups based on study design (randomizedcontrolled trials (RCT), non-randomized comparative, and registry studies). The quality of evidence was assessed usingthe GRADE. The risk of bias was assessed using the Cochrane collaboration’s tool and the MINORS criteria.Results: This meta-analysis included twelve RCTs, three nonrandomized comparative studies and two registry studies,including 38,772 THAs (10,909 CoPE and 27,863 CoC). Overall revision showed a lower risk in CoPE compared to CoCin the two registry studies (HR 0.71 (95%CI 0.53; 0.99)) (very low-quality GRADE evidence). In RCTs and nonrandomizedcomparative studies, no difference was observed (low-quality GRADE evidence). Loosening, dislocation, infection, andpostoperative periprosthetic fracture showed no significant differences in risk ratio for all designs.Conclusion: The lower risk of overall revision in registry studies of primary THA with a press-fit modular cup usingCoPE bearing compared to CoC should be considered preliminary since this outcome was just slightly significant,based on very low-quality GRADE evidence and based on only two studies with several limitations. Since nodifference was observed in the other methodological designs and the separate reasons for revision showed nosignificant difference in all designs either, no preference for CoC or CoPE can be expressed, and therefore bothseem a suitable options based on the available literature. More comparative long-term studies are needed toconfirm the potential advantages of wear-reduction of both bearings since the currently available literature is limited.Level of evidence: I
کلیدواژه‌های انگلیسی مقاله ceramic-on-ceramic, ceramic-on-polyethylene, press-fit, Revision, Total hip arthroplasty

نویسندگان مقاله | Justin van Loon
1 Amsterdam University Medical Centres, location Academic Medical Center, University of Amsterdam, Department of Orthopaedic Surgery, Amsterdam Movement Sciences Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands 2 Xpert Clinics Orthopedie, Laarderhoogtweg 12, 1101EA Amsterdam, The Netherlands 3 Tergooi, department of Orthopaedic Surgery, Van Riebeeckweg 212, 1213 XZ, Hilversum, The Netherlands


| Jan Jaap de Graeff
Leiden University Medical Center, department of Orthopaedic Surgery, Albinusdreef 2, 2333 ZA Leiden, The Netherlands


| Inger Sierevelt
Xpert Clinics Orthopedie, Laarderhoogtweg 12, 1101EA Amsterdam, The Netherlands- Spaarne Gasthuis, Spaarne Gasthuis Academy, Spaarnepoort 1, 2134 TM Hoofddorp, The Netherlands


| Kim Opdam
Amsterdam University Medical Centres, location Academic Medical Center, University of Amsterdam, Department of Orthopaedic Surgery, Amsterdam Movement Sciences Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands


| Rudolf Poolman
Leiden University Medical Center, department of Orthopaedic Surgery, Albinusdreef 2, 2333 ZA Leiden, The Netherlands- OLVG, department of Orthopaedic Surgery, Oosterpark 9, 1091 AC Amsterdam, The Netherlands


| Gino Kerkhoffs
Amsterdam University Medical Centres, location Academic Medical Center, University of Amsterdam, Department of Orthopaedic Surgery, Amsterdam Movement Sciences Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands


| Daniël Haverkamp
Xpert Clinics Orthopedie, Laarderhoogtweg 12, 1101EA Amsterdam, The Netherlands



نشانی اینترنتی https://abjs.mums.ac.ir/article_21144.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده SYSTEMATIC REVIEW
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات