این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 23 آذر 1404
The Archives of Bone and Joint Surgery
، جلد ۱۰، شماره ۷، صفحات ۶۲۱-۶۲۶
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Sonoelastography of Multifidus, Piriformis, Quadratus Lumborum, and Gluteus Medius Muscles in Patients with Unilateral Discogenic Lumbar Pain and Healthy Subjects: A Reliability Study
چکیده انگلیسی مقاله
Background: This study aimed to estimate the within-day and between-day reliabilities of sonoelastography to measurethe strain ratios of lumbopelvic muscles, including multifidus (MF), piriformis (P), quadratus lumborum (QL), and gluteusmedius (GM), in a resting position by the sonoelastography device in both patients with unilateral discogenic lumbarpain and healthy individuals. Failthe treatment of deep infection of peri-articular fracture fixation.Methods: First of all, the participants (n=25) were enrolled in this study, including patients (n=15) and healthy subjects(n=10). In the first session, an examiner estimated the strain ratio of lumbopelvic muscle three times by sonoelastography.The last session was held at a one-week interval. The collected data were analyzed using an intraclass correlationcoefficient (ICC) and a standard error of measurement.Results: The ICC calculated for MF, P, QL, and GM measurements indicated good to excellent reliabilities in bothhealthy and patient groups for within- and between-intra-examiner reliabilities, which were obtained at 0.94-0.91 and0.86-0.86, 0.87-0.89 and 0.82-0.82, 0.88-0.86 and 0.86-0.86, 0.88-0.84 and 0.84-0.84, respectively. Furthermore, thestandard errors of intra-examiner reliability for MF, P, QL, and GM strain ratio measurements in both healthy andsubject groups were estimated at the ranges of 0.52-0.51 and 0.64-0.65, 0.60-0.62 and 0.77-0.78, 0.23-0.25 and 0.25-0.25, 0.25-026 and 0.30-0.35, respectively.Conclusion: The results revealed that sonoelastography seemed to be a reliable instrument to measure MF, P, QL,and GM muscle strain ratios in healthy subjects and patients with unilateral lumbar radicular pain. However, furtherstudies are recommended to support the findings of the present study in other patients.Level of evidence: III
کلیدواژههای انگلیسی مقاله
lumbar radicular pain, sonoelastography, strain ratio, Trigger points
نویسندگان مقاله
| Hossein Rafsanjani Deh Qazi
Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
| Mohammad Mohseni Bandpei
Pediatric Neurorehabilitation Research Center, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran, and Visiting Professor, University Institute of Physical Therapy, Faculty of Allied Health Sciences, University of Lahore, Lahore, Pakistan
| Nahid Rahmani
Pediatric Neurorehabilitation Research Center, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
نشانی اینترنتی
https://abjs.mums.ac.ir/article_19111.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
RESEARCH PAPER
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات