این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 28 آذر 1404
The Archives of Bone and Joint Surgery
، جلد ۱۰، شماره ۵، صفحات ۴۳۲-۴۳۸
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Hybrid Cementation Technique Using the New Modular System for Aseptic Knee Arthroplasty Revision Surgery
چکیده انگلیسی مقاله
Background: To evaluate the clinical and radiological outcomes of aseptic revision of total knee arthroplasty (TKA) using the Vanguard 360 Revision Knee System with the hybrid cementation technique.Methods: Between January 2014 and October 2016, nineteen aseptic revision TKAs were carried out with the Vanguard 360 Revision Knee System (Zimmer-Biomet, Warsaw, IN, USA) performed by two different surgeons. The patients were evaluated clinically and radiographically at one, six, and twelve months after surgery and yearly thereafter. Functional outcomes were assessed according to the range of motion (ROM), knee society knee score (KSKS) and knee society function score (KSFS). Radiological evaluations were performed using the hip-knee-ankle angle (HKA), weight-bearing anteroposterior view, latero-lateral view, Rosenberg x-rays of the knee and skyline patellar x-rays. A triple-phase technetium bone scan was performed on all the patients complaining of knee pain after one year from surgery.Results: Clinical and radiological results including KSKS, KSFS, ROM and HKA angle improved after revision of TKA with a statistically significant difference (P< 0.05). There were seven revisions of the CCK prosthesis due to persistent pain. Conclusion: Patients who underwent revision of TKA using the Vanguard 360 with the hybrid cementation technique had a failure rate of 36.8% at a mean time of 29 months due to aseptic loosening. Further studies are required to analyse the role of cementation in detail to prevent this complication.Level of evidence: IV
کلیدواژههای انگلیسی مقاله
hybrid cementation, knee revision, vanguard 360
نویسندگان مقاله
| Alessio Biazzo
Hip and Knee Reconstructive Surgery Department, Humanitas Gavazzeni, Bergamo, Italy
| Riccardo D’Ambrosi
IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| Eric Staals
Orthopedic Oncology Division, Rizzoli Orthopedic Institute, Bologna, Italy
| Francesco Masia
Hip and Knee Reconstructive Surgery Department, Humanitas Gavazzeni, Bergamo, Italy
| Francesco Verde
Hip and Knee Reconstructive Surgery Department, Humanitas Gavazzeni, Bergamo, Italy
نشانی اینترنتی
https://abjs.mums.ac.ir/article_18649.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
RESEARCH PAPER
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات