این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
شنبه 29 آذر 1404
Iranian Journal of Medical Physics
، جلد ۲۰، شماره ۱، صفحات ۱۹-۳۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Quality of Radiosurgical Plans by Leksell Gamma Knife Perfexion in the Treatment of Meningioma: Comparison between two isodose lines (50% and 75%)
چکیده انگلیسی مقاله
Introduction: Radiosurgery is a well-established available technique for treating many diseases and indications. Planning quality assessment is a crucial step in the procedure itself and outcome probabilities; either control or complication probability. Several physical indices and methodology have been developed to describe any plan. Accordingly, plan quality and outcome could be compared with other plans. In current study, the aim was to compare two plans with different isodose line using radiobiological model, tumor control probability (TCP), normal tissue complication probability (NTCP) and plan’s physical indices. Material and Methods: The cross-sectional study included 20 patients (5 male and 15 female) with median age of 44 years (21-66) and presented with radiologically diagnosed meningioma. Two radiosurgical forward plans were applied with same marginal dose of 12Gy at two different isodose lines of 50% and 75% isodose alternatively using Leksell Gamma Plan of single session GKS. Dose-Volume Histogram (DVH) was imported to MATLAB to compute TCP, NTCP values at 5 years for each plan, and physical indices such as coverage, selectivity, conformity, heterogeneity, and gradient indices.Results: Median target irradiated volume was 7.5 cm3 (0.588 -23.72). TCP was significantly higher in the plan using 50% isodose line for the marginal dose than that using 75% isodose line (95.05%, 49.44%, p< 0.05, Independent Samples t-Test). Brainstem and optic apparatus NTCPs were very low 0.01% (0-0.045%) in the former plan and zero in the later one (p =0.001, Mann-Whitney test).Conclusion: Radiobiological models and physical indices could be used for the optimum plan selection of GKS
کلیدواژههای انگلیسی مقاله
Gamma Knife radiosurgery, Tumor control probability, Normal tissue complication probability, Dose Volume Histogram, Treatment Planning Parameters
نویسندگان مقاله
| Gad Elbaz
Gamma knife unit ,Neurosurgery department,faculty of Medicine AL-Azhar university,Damietta,Egypt.
| Hedaya Hendam
Gamma knife Damietta Center, Department of Neurosurgery, faculty of medicine, Damietta Azhar university Hospital. Cairo, Egypt.
| Elsayed Alashkar
Biophysics Branch, Physics Department, Faculty of Science, Cairo Azhar University. Cairo, Egypt.
| Hussein ABOUELGHEIT
M.D of Neurosurgery ,Stereotaxy and Functional Neurosurgery Unit, Neurological Surgery Department, Tanta University, Egypt. Marseille, Aix Marseille, 264 Rue Saint Pierre, Marseille-13006, Marseille-France
| Khairy Ereiba
Biophysics Branch, Physics Department, Faculty of Science, Cairo Azhar University. Cairo, Egypt
| Ehab Attalla
Department of Radiotherapy and Nuclear Medicine, National Cancer Institute, Cairo;University, Cairo, Egypt
نشانی اینترنتی
https://ijmp.mums.ac.ir/article_19680.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات