این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۲۰، شماره ۱، صفحات ۴۲-۴۷

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Evaluation of Contrast to Noise Ratio of Targeted and Non-Targeted Gold nanoparticles in nasopharyngeal cancer cells in CT images
چکیده انگلیسی مقاله Introduction: In this study, we aimed to identify the benefits in image contrast enhancement of Folic acid-Cysteamine conjugated gold nanoparticles (FA-Cys-AuNPs) by comparing Contrast to Noise ratio (CNR) of gold nanoparticles (AuNPs) to iodinated compound CT images. The CNR was assessed in different tube voltages, concentrations, and incubation times in nasopharyngeal KB cancer cells. Material and Methods: FA-Cys-AuNPs and Omnipaque suspension were scanned at different concentration ranges (500-2000 µg/ml) and energy ranges (80- 140 kVp) with CT imaging modality. FA-Cys-AuNPs and AuNPs were incubated in nasopharyngeal cancer cells at different incubation times (6, 12, and 24 h) and concentration ranges (200-500 µM). Finally, the contrast enhancement was assessed using CNR value at different tube voltages. Results: Results showed that the formed FA-Cys-AuNPs with an Au core size of 15 nm in all concentrations and tube potentials from 80 to 140 kVp display greater CNR than Omnipaque. The CNR value was increased by increasing concentration and energy. At 140 kVp and 2000 µg/ml, the CNR value of FA-Cys-AuNPs was 2.25 times greater than Omnipaque. At 140 kVp, 500 µM and 24 h incubation, the CNR values of targeted cells were approximately 1.5 times higher than non-targeted cells. At 140 kVp, and 500 µM, the CNR value of targeted cells with 24 h incubation time was 2.66 times greater than the targeted cells incubated with 6 h. Conclusion: These findings suggested that the designed FA-Cys-AuNPs could be a good candidate contrast agent for molecular CT imaging.
کلیدواژه‌های انگلیسی مقاله folic acid, Molecular imaging, CT, Gold Nanoparticle, Cancer

نویسندگان مقاله | Sara Khademi
Department of Radiology Technology, School of Paramedical and Rehabilitation Sciences, Mashhad University of Medical Sciences, Mashhad, Iran


| Hosein Azimian
Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran


| Hossein Ghadiri
Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran



نشانی اینترنتی https://ijmp.mums.ac.ir/article_19577.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات