این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 24 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۹، شماره ۴، صفحات ۲۵۸-۲۶۳
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Evaluation of Low-Dose 3D Skull CT Images in Craniosynostosis
چکیده انگلیسی مقاله
Introduction: Computed Tomography (CT) is nowadays used widely to differentiate normal brain cranium sutures from abnormal ones in pediatric patients with the aim of early treatment. This study tried to develop a low-dose CT protocol with the acceptable image quality of skull bone in order to evaluate craniosynostosis.Material and Methods: In this study a cranium bone of human cadaver was scanned with standard and reduced dose protocols. Two radiologists verified the quality of skull bone images acquired from the protocol in which there had been 60% dose reduction to scan pediatric patients. The quality of low dose protocol of three dimensional (3D) CT images of skull bone of 57 pediatric subjects suspected of craniosynostosis were compared with standard-dose skull CT images of 44 patients of the same age range. Volume CT dose index (CTDIvol), dose-length product (DLP), and effective dose (ED) were used to evaluate CT dose protocols. The comparison was made by two sample t-test.Results: Mean and standard deviations of CTDIvol, DLP, and ED of standard and reduced doses were 12.4±2.7 mGy, 191.5±54 mGy.cm, 1.94±0.58 mSv and 5.4±0.2 mGy, 85±9 mGy.cm, 0.77±0.17 mSv, respectively, which had statistically significant difference (α=0.05). The quality of skull bone views obtained from low-dose CT protocol were found to be as good as in standard dose. Conclusion: Standard-dose 3D CT protocol of skull bone can be replaced by a 60%-reduced-dose 3D CT protocol with comparable image quality in pediatric patients suspected of craniosynostosis.
کلیدواژههای انگلیسی مقاله
X, ray Computed Tomography Craniosynostoses Quality Control Radiation Protection
نویسندگان مقاله
| Fariba Zarei
Medical imaging research center, Shiraz university of medical sciences, Shiraz, Iran
| Zeynab Mashayekhi
Department of Radiology, School of Medicine, Shiraz University of Medical Sciences, Shiraz 7134845794, Iran.
| Vani Vardhan Chatterjee
Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore 560012. INDIA
| Sabysachi chatterjee
Retired Scientist from Indian Institute of Astrophysics, present affiliation: Ongil, 79 D3, Sivaya Nagar, Reddiyur Alagapuram, Salem 636004. India.
| Rezvan Ravanfar Haghighi
Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
نشانی اینترنتی
https://ijmp.mums.ac.ir/article_19078.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات