این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 25 آذر 1404
International Journal of Nonlinear Analysis and Applications
، جلد ۱۲، شماره ۲، صفحات ۱۳۵۳-۱۳۷۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
A secure ECG signal transmission for heart disease diagnosis
چکیده انگلیسی مقاله
Due to the high sampling rate, the recorded Electrocardiograms (ECG) data are huge. For storing and transmitting ECG data, wide spaces and more bandwidth are therefore needed. The ECG data are also very important to preprocessing and compress so that it is distributed and processed with less bandwidth and less space effectively. This manuscript is aimed at creating an effective ECG compression method. The reported ECG data are processed first in the pre-processing unit (ProUnit) in this method. In this unit, ECG data have been standardized and segmented. The resulting ECG data would then be sent to the Compression Unit (CompUnit). The unit consists of an algorithm for lossy compression (LosyComp), with a lossless algorithm for compression (LossComp). The randomness ECG data is transformed into high randomness data by the failure compression algorithm. The data's high redundancy is then used with the LosyComp algorithm to reach a high compression ratio (CR) with no degradation. The LossComp algorithms recommended in this manuscript are the Discrete Cosine Transform (DCT) and Discrete Wavelet Transform (DWT). LossComp algorithms such as Arithmetic Encoding (Arithm) and Run Length Encoding (RLE) are also suggested. To evaluate the proposed method, we measure the Compression Time (CompTime), and Reconstruction Time (RecTime) (T), RMSE and CR. Simulation results suggest the highest output in compression ratio and in complexity by adding RLE after the DCT algorithm. The simulation findings indicate that the inclusion of RLE following the DCT algorithm increases performance in terms of CR and complexity. With CR = 55% with RMSE = 0:14 and above 94% with RMSE = 0:2, DCT as a LossComp algorithm was utilized initially, followed by RLE as a LossComp algorithm.
کلیدواژههای انگلیسی مقاله
ECG (Electrocardiogram), Compression ratio (CR), Signal quality
نویسندگان مقاله
Azmi Shawkat Abdulbaqi |
College of Computer Science & Information Technology, University of Anbar, Iraq
Abbas Abdulazeez Abdulhameed |
Department of Computer Science, College of Science, AL Mustansiriyah University, Iraq.
Ahmed J Obaid |
Faculty of Computer Science and Mathematics, University of Kufa, Iraq.
نشانی اینترنتی
https://ijnaa.semnan.ac.ir/article_5235_25f8997851bde771ff02f02c324322f4.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات