این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 23 آذر 1404
International Journal of Organ Transplantation Medicine
، جلد ۱۳، شماره ۳، صفحات ۰-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Estimation of right hemiliver graft weight for living donor liver transplantation using portal vein diameter - a "second checkpoint"
چکیده انگلیسی مقاله
Background Estimation of graft weight for live donor liver transplant using portal vein diameter has not been validated widely. Objective To observe the accuracy of portal vein diameter based formula in predicting graft weight. Methods Graft weight was estimated using standard liver volume (SLV) multiplied by the ratio of portal vein branch diameter (Lee’s formula). SLV was calculated using different formulae described in the literature. The most accurate formula was compared with three dimensional computed tomography volumetry in terms of accuracy of prediction of actual graft weight. Factors which predicted percentage error of more than 15 in computed tomography were analyzed. Results In 307 right hemiliver grafts, SLV calculation by Urata’s method in Lee’s formula was the most accurate (P=0.60 in Analysis of Variance) among all SLV methods. Lee’s formula with Urata and computed tomography volumetry had a good correlation with actual graft weight (r=0.77 vs. r=0.8) which was confirmed by Bland Altman analysis. On volumetry 45 patients had a percent error of more than 15. On logistic regression analysis, an estimated graft volume of greater than 800cc was a significant factor ( p=0.008, odds ratio 2.99) and, in these patients Lee’s formula was better(mean error 9.2 ±7.8 vs. 20.2±4.5, p< 0.001). Conclusions Lee's formula with SLV by Urata’s method was accurate and can act as the second checkpoint after three dimensional computed tomography volumetry. Computed tomography estimate of graft weight more than 800 is associated with higher inaccuracy and in those patients portal vein diameter based formulae fared better.
کلیدواژههای انگلیسی مقاله
Portal Vein,Living Donors,Liver Transplantation,Hepatectomy
نویسندگان مقاله
| Piyush Kumar Sinha
Institute of Liver & Biliary Sciences
| Nihar Ranjan Mohapatra
Institute of Liver & Biliary Sciences
| Shalini Thapar
Institute of Liver & Biliary Sciences
| Viniyendra Pamecha
Institute of Liver & Biliary Sciences, D1 Vasant Kunj, New Delhi, India
نشانی اینترنتی
http://www.ijotm.com/ojs/index.php/IJOTM/article/view/790
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Articles
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات