این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 24 آذر 1404
The Archives of Bone and Joint Surgery
، جلد ۱۱، شماره ۴، صفحات ۲۵۶-۲۶۱
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Ten-Segment Classification has Lowest Inter/IntraObserver Reliability as Compared to Schatzker, ThreeColumn and AO Systems for Tibial Plateau Fractures: A Comparison Based on Surgeons' Experience
چکیده انگلیسی مقاله
Objectives: The primary aim of this study was to assess the reliability of the ten -segment classification system proposed (TSC) by Krause et al. and see how it compares with the traditionally used Schatzker classification, AO classification system, and Luo’s “Three columns” classification (ThCC) system. The second aim of this study was to assess the inter-observer reliability of the above classifications based on professional experience by comparing the entry level of residents (1 year into postgraduation), senior residents (1 year after postgraduation completion), and faculty (>10 years after postgraduation completion).Methods: 50 TPFs were classified by a 10-segment classification system, and its intra-observer (at 1-month interval) and inter-observer reproducibility was checked using k values by three different groups with varying levels of experience (Group I, II, and III comprised of 2 juniors residents, senior residents and consultants each), and the same was compared for three other common classification systems (Schatzker, AO and 3 –column).Results: 10-segment classification showed least k for both inter-observer (0.08) and intra-observer (0.03) reliability. Highest individual inter-observer (k= 0.52) and intra-observer reliability (k= 0.31) was for Schatzker classification in Group I. Lowest individual inter-observer and intra-observer reliability was seen for 10-segment classification (k= 0.07) and AO classification system (k= -0.03) respectively.Conclusion: 10-segment classification showed the lowest k for both inter-observer and intra-observer reliability. The inter-observer reliability for the Schatzker, AO, and 3- column classifications reduced with increasing experience of the observer (JR>SR>Consultant). A possible reason could be a more critical evaluation of the fractures with increasing seniority. Level of evidence: I
کلیدواژههای انگلیسی مقاله
Clinical competence, Computer-assisted, Image Processing, Observer variation, Tomography, X-Ray Computed
نویسندگان مقاله
| Nitesh Gahlot
Department of Orthopaedics, SMS Medical College, Jaipur, Rajasthan, India
| Kishore Kunal
Department of Orthopaedics, All India Institute of Medical Sciences (AIIMS), Jodhpur, India
| Abhay Elhence
Department of Orthopedics, All India Institute of Medical Sciences (AIIMS), Jodhpur, India
| Umesh Meena
Department of Orthopaedics, SMS Medical College, Jaipur, Rajasthan, India
| Akshat Gupta
All India Institute of Medical Sciences (AIIMS), Jodhpur, India
| Jeshwanth Netaji
All India Institute of Medical Sciences (AIIMS), Jodhpur, India
| Dharampal Swami
Department. of Orthopaedics, All India Institute of Medical Sciences (AIIMS), Jodhpur, India
| Meghal Goyal
Department. of Orthopaedics, All India Institute of Medical Sciences (AIIMS), Jodhpur, India
| Ashraf Jamal
Department. of Orthopaedics, All India Institute of Medical Sciences (AIIMS), Jodhpur, India
نشانی اینترنتی
https://abjs.mums.ac.ir/article_21967.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
RESEARCH PAPER
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات