این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Microbiology، جلد ۱۵، شماره ۲، صفحات ۲۲۵-۲۳۵

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Microbial profile and antibiotic resistance pattern of water supply in a tertiary care hospital of Uttarakhand
چکیده انگلیسی مقاله Background and Objectives: In healthcare settings, hospital water and water-related devices can act as a reservoir for waterborne infections. Potable water, sinks, faucet aerators, showers, tub immersion, toilets, dialysis water, water baths, eyewash stations, and dental-unit water stations have all been linked to nosocomial outbreaks. This study aimed to determine the microbial profile and pattern of antibiotic resistance in the water supply of a tertiary care hospital in Uttarakhand. Materials and Methods: This is a 1-year prospective study which was carried out by the Department of Microbiology and Immunology at Sri Mahant Indersh Hospital (SMIH), Dehradun. A total of 154 water samples were collected from the AC outlets, ventilators in the Intensive care unit (ICUs), Operation theatre (OTs), and High dependency unit (HDUs), scrub stations, pantry, and blood bank, patient’s bathroom, private ward, septic ward, labour room, transplant unit, laboratory, scope rinse water, the dialysis unit and tank throughout the hospital, including tap water (pre and post flush [25%]), tap swabs (24%), drinking water (9%), AC outlets (13%), and other areas (3%). Results: 30 of the 154 (19.5%) water samples tested were culture-positive. The most contaminated water samples were tap swabs (27%, n = 8/30). A total of nine organisms were isolated, of which the most predominant was Pseudomonas aeruginosa (40%; 12/30), followed by Legionella pneumophila (13%; 4/30), Acinetobacter baumanii (10%; 3/30), Klebsiella pneumoniae (10%; 3/30), Escherichia coli (7%; 2/30), Enterococcus faecalis (7%; 2/30), Aspergillus flavus (7%; 2/30), Stenotrophomonas (3%; 1/30), and Fusarium spp. (3%; 1/30). Gram-negative bacilli and non-lactose fermenting (GNB and NLF) showed a high rate of contamination, 53.3% (n = 16/30). P. aeruginosa showed resistance to gentamicin and amikacin (42%), imipenem (50%), levofloxacin (58%), and colistin (25%), while Acinetobacter baumanii showed resistance to gentamicin and amikacin (67%), minocycline (63%), and levofloxacin, imipenem and colistin (33%). Conclusion: The study's findings show that a variety of microorganisms are contaminating hospital water supplies and can be a source of hospital-acquired infections. A suitable and robust surveillance program for hospital water supplies, as well as strict adherence to infection control practices, is strongly advised.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله | Lipika Gaur
Department of Microbiology and Immunology, Shri Mahant Indersh Hospital, Dehradun, Uttarakhand, India


| Iva Chandola
Department of Microbiology and Immunology, Shri Mahant Indersh Hospital, Dehradun, Uttarakhand, India


| Nidhi Negi
Department of Microbiology and Immunology, Shri Mahant Indersh Hospital, Dehradun, Uttarakhand, India


| Pankaj Rawat
Department of Microbiology and Immunology, Shri Mahant Indersh Hospital, Dehradun, Uttarakhand, India



نشانی اینترنتی https://ijm.tums.ac.ir/index.php/ijm/article/view/4087
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات