Iranian Journal of Medical Physics، جلد ۲۰، شماره ۳، صفحات ۱۳۶-۱۴۵

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Tissue Substitute Materials for the Human Colorectal Cancer Tissue
چکیده انگلیسی مقاله Introduction: Due to the high radiation dose used in radiotherapy, the human tissue is usually replaced with tissue substitutes in order to develop new treatment techniques. Tissue substitutes have not been reported for colorectal cancer tissue (CRC). This study aims at developing tissue substitutes for the CRC tissue with respect to the mass attenuation (µm) and mass energy absorption coefficients (µen/ρ) within the energy range of 6 – 15MV. Material and Methods: Colorectal cancer tissue and four locally sourced materials namely beeswax, gelatine, rice powder, clay, and their mixtures – Clarice, gelarice, gelaclay, and bewaclay were subjected to Rutherford Backscattering Spectrometry (RBS) to determine their elemental composition. Results from the RBS were used in XCOM, a web-based photon interaction software designed by the National Institute of Standards and Technology, USA to determine their theoretical µm and µen/ρ values. Again, these materials were exposed to a narrow beam of x-rays at energies of 6 and 15MV to obtain their experimental µm and µen/ρ values. Results: Revealed that the ratio of CRC tissue to the test materials ranged from 0.946 (beeswax) to 1.07 (clay) for both theoretical and experimental values with bewaclay having a ratio of 1.01 compared with 1.00 for CRC and a p = 0.541 and p = 0.663 with respect to µm and µen/ρ respectively. Conclusion: Bewaclay with the closest match can be used as a tissue substitute for the CRC tissue between 6 – 9MV with respect to µm and µen/ρ as parameters for matching.
کلیدواژه‌های انگلیسی مقاله Mass Attenuation Coefficient, mass energy absorption coefficient, Radiotherapy, Cancer

نویسندگان مقاله | Emmanuel Esien-umo
Department of Radiography and Radiological Science, Faculty of Allied Medical Sciences, University of Calabar, Calabar, Cross River State


| Joseph Obu
Department of Physics, Faculty of Physical Sciences, University of Calabar


| Ndubuisi Chiaghanam
Department of Radiography and Radiological Science, University of Calabar, Calabar-Nigeria


| Akwa Erim
Department of Radiography and Radiological science, Faculty of allied medical sciences, University of Calabar, Calabar, Cross River State, Nigeria


| Nneoyi Egbe
Department of Radiography & Radiological Science, University of Calabar, Nigeria



نشانی اینترنتی https://ijmp.mums.ac.ir/article_20456.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات