این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۲۰، شماره ۳، صفحات ۱۴۶-۱۵۲

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Dosimetric Comparative Study between Single and Dual Isocenter Stereotactic Body Radiotherapy Plans in Treatment of Multiple Lesions Non-Small Cell Lung Cancer Patients
چکیده انگلیسی مقاله Introduction: stereotactic body radiotherapy (SBRT) is the most proper treatment for multi lesions non-small cell lung cancer (NSCLC) for enhanced good coverage and minimizing dose to organs at risk (OARs). This study aims to compare single and dual isocenter SBRT plans and discuss which technique we can use in multi lesions NSCLC. Material and Methods: Ten patients with multi targets NSCLC underwent two different SBRT treatment planning techniques including single isocenter and dual isocenter. We quantitatively assessed plans qualities by dose-volume metrics. Conformity index (CI), Confirmation Number (CN), heterogeneity index (HI), gradient distance (GD), Gradient index (GI), and maximum percentage dose at 2cm all around PTV ( ) were gathered, tallied, and statistically examined. OARs were evaluated and the dose to the normal lung was evaluated using V5, V10, V20, and mean lung dose (MLD). Results: There is an insignificant difference between single and dual isocenter plans in CI, CN, HI, GD, GI, and dose spillage where the mean distance between two lesions was 5.50 ± 1.50 cm, and the mean total volume of the planning target volume (PTV) was 42.60±21.33cc. For single and dual isocenter plans, the median MLD was 4.5(2-16)Gy and 4 (2-16)Gy respectively (p=0.25). Conclusion: Plan quality of single isocenter was equal to dual isocenter for SBRT treatment of multi lung lesions with maximum distances between them was 10 cm. Dual isocenter took time during setup and matching for cone beam computed tomography (CBCT).
کلیدواژه‌های انگلیسی مقاله Stereotactic Body Radiotherapy, VMAT, Lung cancer

نویسندگان مقاله | Mona Ibraheim
Physics Department, Faculty of Science, Zagazig University, Zagazig, Egypt.


| Magda Hanafy
Physics Department, Faculty of Science, Zagazig University, Zagazig, Egypt.


| Khaled El-Shahat
Clinical Oncology and Nuclear Medicine Department, Faculty of Medicine, El-Azhar University, Cairo, Egypt


| Mohammed Bayomy
Clinical Oncology and Nuclear Medicine Department, Faculty of Medicine, ZagazigUniversity, Zagazig, Egypt.


| Hany Attallah
Radiation Oncology Department, International Medical Center (IMC), Egypt.


| Nesma khalil
Clinical Oncology and Nuclear Medicine department, Zagazig University Hospitals, Egypt.



نشانی اینترنتی https://ijmp.mums.ac.ir/article_20355.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات