Comparison of Image Quality According To Application of CT Algorithms for Acquisition of Clinical Information: A Phantom Study
چکیده انگلیسی مقاله
Introduction: While various algorithms are applied in acquiring diagnostic information during computed tomography, such algorithms may affect image quality. The present study aimed to investigate the changes in image quality according to the application of the metal reduction algorithm and monoenergetic image in standard imaging.Material and Methods: Spectral computed tomography was used to acquire images with the application of standard, metal artifact reduction, monoenergetic, and monoenergetic+metal artifact reduction under the same conditions according to without or with of metal in ACR phantom. ImageJ program was used to measure the HU, noise, and SNR of polyethylene, bone, and acrylic located inside the ACR phantom using the same-sized ROIs.Results: HU measurement results showed changes in all materials, except acrylic with metal artifacts in the images. Moreover, the results showed a decrease in HU in images with the application of monoenergetic. Noise measurement results also showed changes in all materials, except acrylic with metal artifacts in the images. Moreover, the results showed a decrease in noise in images with the application of monoenergetic. For SNR measured relative to standard images, the results showed degradation of image quality due to a decrease of 36.5–77.7% in SNR and an increase in error value in all materials except acrylic. Whereas, acrylic showed an increase of 3.2–4.1% and a decrease in error values, resulting in improved image quality.Conclusion: Therefore, it is believed that the accuracy of reading could be increased by considering the changes in image quality and characteristics when applying algorithms for acquiring clinical information from CT.
کلیدواژههای انگلیسی مقاله
Spectral CT, Hounsfield Unit, SNR, metal reduction, monoenergetic imaging
نویسندگان مقاله
| gui chul Lee
Seoul National University Bundang Hospital, Department of Radiology, Department of Healthcare, Graduate School ,Eulji University, Republic of Korea
| Dongkyoon Han
Department of Radiological Science, Seongnam-si, Gyeonggi-do, Republic of Korea
| Joowan Hong
Department of Radiological Science, Seongnam-si, Gyeonggi-do, Republic of Korea
نشانی اینترنتی
https://ijmp.mums.ac.ir/article_20655.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات