Iranian Journal of Medical Physics
، جلد ۱۳، شماره ۳، صفحات ۱۵۴-۱۶۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Calculation of the X-Ray Spectrum of a Mammography System with Various Voltages and Different Anode-Filter Combinations Using MCNP Code
چکیده انگلیسی مقاله
Introduction One of the best methods in the diagnosis and control of breast cancer is mammography. The importance of mammography is directly related to its value in the detection of breast cancer in the early stages, which leads to a more effective treatment. The purpose of this article was to calculate the X-ray spectrum in a mammography system with Monte Carlo codes, including MCNPX and MCNP5. Materials and Methods The device, simulated using the MCNP code, was Planmed Nuance digital mammography device (Planmed Oy, Finland), equipped with an amorphous selenium detector. Different anode/filter materials, such as molybdenum-rhodium (Mo-Rh), molybdenum-molybdenum (Mo-Mo), tungsten-tin (W-Sn), tungsten-silver (W-Ag), tungsten-palladium (W-Pd), tungsten-aluminum (W-Al), tungsten-molybdenum (W-Mo), molybdenum-aluminum (Mo-Al), tungsten-rhodium (W-Rh), rhodium-aluminum (Rh-Al), and rhodium-rhodium (Rh-Rh), were simulated in this study. The voltage range of the X-ray tube was between 24 and 34 kV with a 2 kV interval. Results The charts of changing photon flux versus energy were plotted for different types of anode-filter combinations. The comparison with the findings reported by others indicated acceptable consistency. Also, the X-ray spectra, obtained from MCNP5 and MCNPX codes for W-Ag and W-Rh combinations, were compared. We compared the present results with the reported data of MCNP4C and IPEM report No. 78 for Mo-Mo, Mo-Rh, and W-Al combinations. Conclusion The MCNPX calculation outcomes showed acceptable results in a low-energy X-ray beam range (10-35 keV). The obtained simulated spectra for different anode/filter combinations were in good conformity with the finding of previous research.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
لیدا غلامکار | lida gholamkar
department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran,
سازمان اصلی تایید شده
: دانشگاه آزاد اسلامی علوم و تحقیقات (Islamic azad university science and research branch)
مهدی صادقی | mahdi sadeghi
medical physics department, school of medicine, iran university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ایران (Iran university of medical sciences)
علی اصغر مولوی | ali asghar mowlavi
physics department, school of sciences, hakim sabzevari university, sabzevar, iran. ictp, associate federation scheme, medical physics field, trieste, italy.
سازمان اصلی تایید شده
: دانشگاه حکیم سبزواری (Hakim sabzevari university)
میترا اطهری | mitra athari
department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran,
سازمان اصلی تایید شده
: دانشگاه آزاد اسلامی علوم و تحقیقات (Islamic azad university science and research branch)
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_7959.html
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/145/article-145-279206.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات