این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
شنبه 22 آذر 1404
Dental Research Journal
، جلد ۲۰، شماره ۹، صفحات ۰-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
In vitro effect of anodization of titanium abutments on their tensile bond strength to implant‑supported lithium disilicate all‑ceramic crowns
چکیده انگلیسی مقاله
Background: The retention of cement‑retained implant‑supported restorations can be affected by surface treatments such as anodizing. This study aimed to assess the effect of the anodization of titanium abutments on their tensile bond strength to implant‑supported lithium disilicate (LDS) all‑ceramic crowns. Materials and Methods: This in vitro, experimental study was conducted on 26 straight abutments in two groups of anodization and control. In the anodization group, seven flat 9 V batteries connected in series were used to generate 64 V energy. A glass container was filled with 250 mL of distilled water, and 1 g of trisodium phosphate was added to it to create an electrolyte solution. The anode was then disconnected and the abutment was rinsed with acetone and deionized water. The surface roughness of abutments was measured by a profilometer. The abutments were scanned by a laboratory scanner, and maxillary central incisor monolithic crowns were fabricated by inLab SW18 software. The crowns were seated on the abutments and temporarily cemented with TempBond. They were then incubated in artificial saliva and subjected to 5000 thermal cycles. The tensile bond strength of crowns was then measured. Data were analyzed by the Student’s t‑test and Mann–Whitney U‑tests (α =0.05). Results: The mean bond strength was significantly higher in anodized abutments (P = 0.003). The surface roughness of anodized abutments was slightly, but not significantly, higher than that of the control group (P > 0.05). The frequency of adhesive failure was almost twice higher in anodized abutments. Conclusion: Anodization of titanium abutments significantly improved their tensile bond strength to implant‑supported LDS all‑ceramic crowns. Key Words: Dental abutments, dental implants, single‑tooth, surface properties, titanium oxide Highlight Azita Mazaheri Tehrani: Pubmed , Google Scholar
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Hamed Karimi Pour
| Homeira Ansari
| Azita Mazaheri Tehrani
نشانی اینترنتی
http://drj.mui.ac.ir/index.php/drj/article/view/2514
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article(s)
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات