این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۲۰، شماره ۴، صفحات ۲۱۵-۲۲۱

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Radiation Dose Optimization during Temporal Bone CT Examination Using One-Shot Axial Volumetric Acquisition
چکیده انگلیسی مقاله Introduction: The optimization of radiation exposure when exploring small and complex anatomical structures is the most important issue for temporal bone CT. The objective of this study is to use single-shot volume acquisition in order to minimize the dose and compare the obtained image quality to a conventional helical technique. Material and Methods: Twenty patients (8 males, 12 females) were scanned using the 135kVp single-shot volume mode (VMCT135-kVp) whereas other twenty patients (9 males, 11 females) were examined using the 120kVp helical mode (HMCT120-kVp). A physician-interpreter evaluated the subjective conspicuity of 53 structures in the temporal bone on a 5-point scale using multiplanar reconstruction (MPR). In addition, the image noise in both techniques was quantified by analyzing it in three different regions of interest (ROIs). Radiation dose reduction was noted and compared with literature-based effective dose dosimetry data.Results: The mean dose-length-product (DLP) for the VMCT135-kVp was (69.6±2.5 mGy.cm), which was significantly lower (p< 0.001), compared to (186.4±4.3 mGy.cm) for HMCT120-kVp. Similarly, the effective dose (0.15±0.01 mSv) for VMCT135-kVp was reduced by approximately 61.5% relative to (0.39±0.05 mSv) for HMCT120-kVp. In contrast, there was no significant difference in the image noise average between the two protocols (p> 0.05). Indeed, the overall analysis of the 53 anatomic structures revealed no differences between the two protocols, and most anatomic structures were identified.Conclusion: For temporal bone, the VMCT135-kVp scan significantly reduces radiation exposure compared to the HMCT120-kVp. The obtained dose was lower compared to the literature-based protocol while maintaining image visualization quality.
کلیدواژه‌های انگلیسی مقاله Computed Tomography, Volumetric, Temporal bone

نویسندگان مقاله | Youssef Madkouri
Laboratory of Electronic Systems, Information Processing, Mechanics and Energetics, Faculty of Sciences , University Ibn Tofail Kenitra, Kenitra, Morocco


| Mohammed Aggour
Laboratory of Electronic Systems, Information Processing, Mechanics and Energetics, Faculty of Sciences , University Ibn Tofail Kenitra, Kenitra, Morocco


| Youssef Bouzekraoui
Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Sciences and Health Technologies, Settat, Morocco


| FARIDA BENTAYEB
Departement of Physics, Laboratory of High Energy Physics, Modelling and Simulation, Faculty of Science, Mohammed V Agdal University, Rabat, Kingdom of Morocco



نشانی اینترنتی https://ijmp.mums.ac.ir/article_20680.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات