این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 28 آذر 1404
The Archives of Bone and Joint Surgery
، جلد ۱۱، شماره ۱۱، صفحات ۶۸۴-۶۸۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Three-Dimensional Analysis of Metacarpal Head Articular Defects Created by Headless Screws
چکیده انگلیسی مقاله
Objectives: Headless screw fixation used to treat metacarpal neck and metacarpal shaft fractures is gaining popularity. The aim of the study is to determine the proportion of the metacarpal head articular surface that is compromised during retrograde insertion of headless screws. Methods: Metacarpal screw fixation through a metacarpal head starting point was performed using fluoroscopic guidance on 14 metacarpals. Headless compression screws, with a tail diameter of 3.6mm, were used. The specimens were subsequently skeletonized and digitized using a 3-dimensional surface scanner. The articular surface defects created by the screws were then determined using computer software. Screw position in the dorsal aspect of the metacarpal head was expressed as a percentage of the total volar-to-distal distance. Results: The 14 metacarpals studied consisted of 2 index, 4 long, 4 ring and 4 small metacarpals, taken from 4 hands. The average total metacarpal head surface area was 284.6 mm2 (range, 151.0-462.2 mm2); the average screw footprint in the metacarpal head was 13.3 mm2 (range, 10.3-17.4 mm2), which compromised a mean of 5.0% (3.0-7.8%) of the total cartilaginous metacarpal head surface area. In the sagittal plane, screw placement was found to lie in the dorsal 37.4% of the metacarpal head (range, 20.7-58.6%). Conclusion: The proportion of the articular surface area injured with retrograde insertion of headless compression screws into the metacarpal head is 5.0%. Screw placement is generally in the dorsal 37% of the metacarpal head. Level of evidence: V
کلیدواژههای انگلیسی مقاله
Headless screw, Intramedullary screw fixation, metacarpal head, Metacarpal Fracture
نویسندگان مقاله
| Abdo Bachoura
The Philadelphia Hand to Shoulder Center, Thomas Jefferson University Hospital, Philadelphia, PA, USA/Rothman Orthopaedics, Orlando, FL, USA
| Michael Gaspar
The Philadelphia Hand to Shoulder Center, Thomas Jefferson University Hospital, Philadelphia, PA, USA
| Patrick Kane
The Philadelphia Hand to Shoulder Center, Thomas Jefferson University Hospital, Philadelphia, PA, USA
| Derek Bernstein
The Philadelphia Hand to Shoulder Center, Thomas Jefferson University Hospital, Philadelphia, PA, USA
| Mark Rekant
The Philadelphia Hand to Shoulder Center, Thomas Jefferson University Hospital, Philadelphia, PA, USA
| A. Osterman
The Philadelphia Hand to Shoulder Center, Thomas Jefferson University Hospital, Philadelphia, PA, USA
نشانی اینترنتی
https://abjs.mums.ac.ir/article_23269.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
RESEARCH PAPER
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات