این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 21 آذر 1404
Iranian Journal of Fuzzy Systems
، جلد ۸، شماره ۴، صفحات ۹۳-۱۰۵
عنوان فارسی
FLUENCE MAP OPTIMIZATION IN INTENSITY MODULATED RADIATION THERAPY FOR FUZZY TARGET DOSE
چکیده فارسی مقاله
Although many methods exist for intensity modulated radiotherapy (IMRT) fluence map optimization for crisp data, based on clinical practice, some of the involved parameters are fuzzy. In this paper, the best fluence maps for an IMRT procedure were identifed as a solution of an optimization problem with a quadratic objective function, where the prescribed target dose vector was fuzzy. First, a defuzzying
procedure was introduced to change the fuzzy model of the problem into an equivalent non-fuzzy one. Since the solution set was nonconvex, the optimal solution was then obtained by performing a projection operation in applying the gradient method. Numerical simulations for two typical clinical cases (for prostate and head-and-neck cancers, each for two patients) are given.
کلیدواژههای فارسی مقاله
IMRT، Singed distance، Triangular fuzzy number، Gradient method،
عنوان انگلیسی
FLUENCE MAP OPTIMIZATION IN INTENSITY MODULATED RADIATION THERAPY FOR FUZZY TARGET DOSE
چکیده انگلیسی مقاله
Although many methods exist for intensity modulated radiotherapy (IMRT) fluence map optimization for crisp data, based on clinical practice, some of the involved parameters are fuzzy. In this paper, the best fluence maps for an IMRT procedure were identifed as a solution of an optimization problem with a quadratic objective function, where the prescribed target dose vector was fuzzy. First, a defuzzying
procedure was introduced to change the fuzzy model of the problem into an equivalent non-fuzzy one. Since the solution set was nonconvex, the optimal solution was then obtained by performing a projection operation in applying the gradient method. Numerical simulations for two typical clinical cases (for prostate and head-and-neck cancers, each for two patients) are given.
کلیدواژههای انگلیسی مقاله
IMRT, Singed distance, Triangular fuzzy number, Gradient method
نویسندگان مقاله
Alireza Fakharzadeh Jahromi |
Shiraz University of Technology, Shiraz, Fars, Iran
Omolbanin Bozorg |
Shiraz University of Technology, Shiraz, Fars, Iran
Hamidreza Maleki |
Shiraz University of Technology, Shiraz, Fars, Iran
Mohamad Amin Mosleh-Shirazi |
Shiraz University of Medical Sciences, Shiraz, Fars,
نشانی اینترنتی
http://ijfs.usb.ac.ir/article_310_624d131dd630762401d6a0a4997854fa.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات