عنوان انگلیسی Comparison Between 2D Transthoracic Echocardiography, Transesophageal Echocardiography, and Balloon Sizing Methods for Device Size Selection in Pediatric Patients Undergoing Transcatheter Closure of Atrial Septal Defects
چکیده انگلیسی مقاله Background: Transcatheter closure of atrial septal defects (ASDs) is considered an alternative technique to surgery, and appropriate device size selection is essential to an effective procedure. We aimed to compare 2D transesophageal echocardiography (TEE), transthoracic echocardiography (TTE), and balloon sizing methods for device size selection in pediatric patients undergoing ASD transcatheter closure and to establish an accurate and simple procedure for device size selection.   Methods: This cross-sectional study was performed on pediatric patients for 8 months in Tehran, Iran. Device size was identified by balloon sizing, 2D TEE, and TTE.   Results: This study enrolled 39 children (64.1% female, average age= 7.1±3.1 y) who underwent successful ASD transcatheter closure. The mean defect size by balloon-stretched diameter measurement was significantly greater than the ASD size measured by 2D TEE and TTE. There was a strong, highly significant positive correlation (P<0.001) between the device waist size and different ASD diameters measured by 2D TEE, TTE, and balloon sizing. A good linear association was found between the ASD size measured by device waist size and 2D TEE (device waist size= 0.99×TEE-derived defect size+1.678; P<0.001) as well as TTE (device waist size= 1.01×TTE-derived defect size+1.17; P<0.001), respectively.   Conclusions: In this study, TEE and TTE-derived defect sizes were significantly associated with the device waist size. Additionally, the equations generated herein may provide a reliable and good prediction for appropriate device size. (Iranian Heart Journal 2022; 23(1): 74-84)
کلیدواژه‌های انگلیسی مقاله ASD,TTE,TEE,children,Iran

نویسندگان مقاله Ahmad Vesal |
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, IR Iran.

Maryam Moradian |
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, IR Iran.

Mohsen Ghasemnezhad |
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, IR Iran.

Avisa Tabib |
Heart Valve Disease Research Center, Rajaie Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran, IR Iran.

Fariba Rashidi Ghader |
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, IR Iran.

Seyyed Mahmoud Meraji |
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, IR Iran.

Farshad Jafari |
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, IR Iran.

Hamid Reza Ghaemi |
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, IR Iran.

Solmaz Heidari |
Department of Pediatrics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, IR Iran.

Shahriar Barouti |
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, IR Iran.

Shooka Mohammadi |
Rajaie Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences, Tehran, IR Iran.


نشانی اینترنتی http://journal.iha.org.ir/article_142601_7bc72ae0f97912259668e923eaf34962.pdf
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات