این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 25 آذر 1404
Iranian Heart Journal
، جلد ۲۲، شماره ۱، صفحات ۹۱-۹۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Echocardiographic Screening for Myocardial Dysfunction Among Asphyxiated Newborns
چکیده انگلیسی مقاله
Background:
Perinatal asphyxia/ischemia is an interruption in the availability of oxygen supply to the myocardium. We sought to assess myocardial function among asphyxiated and non-asphyxiated neonates using echocardiography.
Methods:
The present case-control study was undertaken at the neonatal intensive care unit (NICU) of a tertiary care hospital. Neonates with asphyxia who were admitted to the NICU were included in the study. The diagnosis of asphyxia was established on the basis of the APGAR score at 1 and 5 minutes. Myocardial function was assessed in terms of serum cardiac troponin I (CTnI) and different echocardiographic parameters such as M-Mode, Doppler flow parameters, and tissue Doppler imaging.
Results:
Thirty asphyxiated (the case group) and 30 non-asphyxiated (the control group) term neonates were enrolled in the study. The asphyxia group had significantly lower (
P
< 0.001) 1- and 5-minute APGAR scores than the controls. The asphyxia group had a higher serum CTnI value. The differences between the 2 groups concerning M-Mode parameters in the first 12 hours of life were statistically significant (
P
< 0.001). The case and control groups were also statistically significantly different regarding left atrial pressure at 48 hours following birth, calculated as a ratio of E/e’ (
P
< 0.001). The differences between the 2 study groups at 24 hours after birth as regards tissue Doppler parameters, including left ventricular ejection time and left ventricular Tei index, were also statistically significant (
P
< 0.001). The case and control groups also showed statistically meaningful differences concerning right ventricular ejection period/ ejection time at 24 hours after birth (
P
< 0.002).
Conclusions:
It can be concluded that the myocardial function assessment using CTnI and different echocardiographic techniques is the most sensitive and specific method in the detection of ischemic cardiac injury in asphyxiated newborns.
(Iranian Heart Journal 2021; 22(1): 91-99)
کلیدواژههای انگلیسی مقاله
Asphyxia,APGAR score,Newborn,Troponin
نویسندگان مقاله
Krishnananda Nayak |
Department of Cardiovascular Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India.
Sara Varghese |
Department of Cardiovascular Technology, School of Allied Health Science, Manipal Academy of Higher Education, Manipal, India.
Abdul Razak |
Department of Cardiology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India.
Megha A |
Department of Cardiovascular Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India.
Tom Devasia |
Department of Cardiology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India.
Leslie Edward Lewis |
Department of Pediatrics, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India.
Sridevi Prabhu |
Department of Cardiovascular Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India.
نشانی اینترنتی
http://journal.iha.org.ir/article_120943_228e08e97d6654790cb2a34a4b8ea52d.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات